One-year outcomes of conventional and accelerated collagen crosslinking in progressive keratoconus
Vanissa W. S. Chow, Tommy C.Y. Chan, Marco Yu, Victoria W. Y. Wong, Vishal Jhanji
Abstract
Open-access reader
Vanissa W. S. Chow, Tommy C.Y. Chan, Marco Yu, Victoria W. Y. Wong, Vishal Jhanji
Abstract
Open-access reader
We compared one-year outcomes of conventional (3 mW/cm(2), 365-nm ultraviolet-A light, 30 minutes) and accelerated (18 mW/cm(2), 365-nm ultraviolet-A light, 5 minutes) collagen crosslinking (CXL) in patients with progressive keratoconus. Main outcome measures were change in keratometry, uncorrected visual acuity (UCVA), and best-corrected visual acuity (BCVA). Nineteen patients in each group completed 1-year follow-up. Preoperatively, there were no inter-group differences for age, keratometry, corneal thickness, and spherical equivalent (p > 0.127). One year postoperatively, maximum and minimum keratometry were flattened by 1.6 diopters (p < 0.023) and 2 diopters (p < 0.047) respectively after conventional CXL, and, 0.47 diopters (p = 0.471) and 0.19 diopters (p = 0.120) respectively after accelerated CXL. Association analysis showed significant negative association between baseline maximum keratometry and change in maximum keratometry after accelerated CXL (p = 0.002) but not after conventional CXL (p = 0.110). Corneal thickness was reduced significantly in both groups (p = 0.017). An improvement in UCVA (p < 0.001) and BCVA (p < 0.022) was noted in both groups along with a reduction in spherical equivalent postoperatively (p < 0.026). There were no inter-group differences for any of the parameters postoperatively (p > 0.184). Although no statistically significant differences were observed between both treatment modalities, a more effective topographic flattening was observed with conventional CXL as compared to accelerated CXL in this study.
OpenAlex reports 105 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We compared one-year outcomes of conventional (3 mW/cm(2), 365-nm ultraviolet-A light, 30 minutes) and accelerated (18 mW/cm(2), 365-nm ultraviolet-A light, 5 minutes) collagen crosslinking (CXL) in patients with progressive keratoconus. Main outcome measures were change in keratometry, uncorrected visual acuity (UCVA), and best-corrected visual acuity (BCVA). Nineteen patients in each group completed 1-year follow-up. Preoperatively, there were no inter-group differences for age, keratometry, corneal thickness, and spherical equivalent (p > 0.127). One year postoperatively, maximum and minimum keratometry were flattened by 1.6 diopters (p < 0.023) and 2 diopters (p < 0.047) respectively after conventional CXL, and, 0.47 diopters (p = 0.471) and 0.19 diopters (p = 0.120) respectively after accelerated CXL. Association analysis showed significant negative association between baseline maximum keratometry and change in maximum keratometry after accelerated CXL (p = 0.002) but not after conventional CXL (p = 0.110). Corneal thickness was reduced significantly in both groups (p = 0.017). An improvement in UCVA (p < 0.001) and BCVA (p < 0.022) was noted in both groups along with a reduction in spherical equivalent postoperatively (p < 0.026). There were no inter-group differences for any of the parameters postoperatively (p > 0.184). Although no statistically significant differences were observed between both treatment modalities, a more effective topographic flattening was observed with conventional CXL as compared to accelerated CXL in this study.
Key concepts: Keratometer, Dioptre, Keratoconus, Corneal collagen cross-linking, Medicine, Ophthalmology, Visual acuity, Corneal topography