2011Journal of the Korean Society of Manufacturing Process EngineersRequires access

A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle

Jae Ung Cho, Moonsik Han

Open publisher page 4 citations

Abstract

This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than .This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.

About this research paper

What this paper is about

This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than .This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than .This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.

Key concepts: Ball valve, Mechanics, Ball (mathematics), Volumetric flow rate, Vortex, Mass flow rate, Pressure drop, Globe valve

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle — Research Paper | ScholarLens