2011•PubMedOpen access

Efficacy and safety of inferior turbinate coblation-channeling in the treatment of nasal obstructions.

Željka Roje, Goran Račić, Goran Kardum

Open full text 5 citations

Abstract

The aim of this study was to evaluate the safety and effectiveness of coblation-channeling in the treatment of inferior turbinate hypertrophy. The study was conducted in the Department of ENT Head and Neck Surgery, Split University Hospital Center, Split, Croatia. Fifty-two patients with inferior turbinate hypertrophy who were refractory to medical therapy were evaluated for coblation. The procedures were performed under local anesthesia using an ArthroCare ReFlexUltra 45 wand; three submucosal channels were made per turbinate. Clinical examinations, a questionnaire on individual nasal symptoms (hyposmia, nasal drainage and post-nasal drip), a 10-cm visual analog scale (VAS) grading general nasal obstructions, and rhinomanometry before and 8 weeks after the treatment were administered to assess treatment outcomes. No adverse effects were encountered. Nasal breathing was significantly improved in all patients, decreasing the VAS from a median of 7 (range 2-9) to 1 (range 0-3) (p < 0.001). Total nasal resistance decreased from 0.44 Pa +/- 0.50 to 0.24 Pa +/- 0.11 (p = 0.005). Improvement was statistically significant for all three symptoms (hyposmia [p = 0.005], nasal drainage [p = 0.003] and post-nasal drip [p < 0.001]). In this paper, we demonstrate that coblation-channeling of the hypertrophic inferior turbinate is an effective and safe way to reduce nasal obstruction symptoms.

Open-access reader

About this research paper

What this paper is about

The aim of this study was to evaluate the safety and effectiveness of coblation-channeling in the treatment of inferior turbinate hypertrophy. The study was conducted in the Department of ENT Head and Neck Surgery, Split University Hospital Center, Split, Croatia. Fifty-two patients with inferior turbinate hypertrophy who were refractory to medical therapy were evaluated for coblation. The procedures were performed under local anesthesia using an ArthroCare ReFlexUltra 45 wand; three submucosal channels were made per turbinate. Clinical examinations, a questionnaire on individual nasal symptoms (hyposmia, nasal drainage and post-nasal drip), a 10-cm visual analog scale (VAS) grading general nasal obstructions, and rhinomanometry before and 8 weeks after the treatment were administered to assess treatment outcomes. No adverse effects were encountered. Nasal breathing was significantly improved in all patients, decreasing the VAS from a median of 7 (range 2-9) to 1 (range 0-3) (p < 0.001). Total nasal resistance decreased from 0.44 Pa +/- 0.50 to 0.24 Pa +/- 0.11 (p = 0.005). Improvement was statistically significant for all three symptoms (hyposmia [p = 0.005], nasal drainage [p = 0.003] and post-nasal drip [p < 0.001]). In this paper, we demonstrate that coblation-channeling of the hypertrophic inferior turbinate is an effective and safe way to reduce nasal obstruction symptoms.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to evaluate the safety and effectiveness of coblation-channeling in the treatment of inferior turbinate hypertrophy. The study was conducted in the Department of ENT Head and Neck Surgery, Split University Hospital Center, Split, Croatia. Fifty-two patients with inferior turbinate hypertrophy who were refractory to medical therapy were evaluated for coblation. The procedures were performed under local anesthesia using an ArthroCare ReFlexUltra 45 wand; three submucosal channels were made per turbinate. Clinical examinations, a questionnaire on individual nasal symptoms (hyposmia, nasal drainage and post-nasal drip), a 10-cm visual analog scale (VAS) grading general nasal obstructions, and rhinomanometry before and 8 weeks after the treatment were administered to assess treatment outcomes. No adverse effects were encountered. Nasal breathing was significantly improved in all patients, decreasing the VAS from a median of 7 (range 2-9) to 1 (range 0-3) (p < 0.001). Total nasal resistance decreased from 0.44 Pa +/- 0.50 to 0.24 Pa +/- 0.11 (p = 0.005). Improvement was statistically significant for all three symptoms (hyposmia [p = 0.005], nasal drainage [p = 0.003] and post-nasal drip [p < 0.001]). In this paper, we demonstrate that coblation-channeling of the hypertrophic inferior turbinate is an effective and safe way to reduce nasal obstruction symptoms.

Key concepts: Medicine, Hyposmia, Rhinomanometry, Visual analogue scale, Turbinates, Surgery, Nose, Nasal cavity

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy and safety of inferior turbinate coblation-channeling in the treatment of nasal obstructions. — Research Paper | ScholarLens