2007PubMedRequires access

[The relationship of individual sensitivities to fentanyl and those to propofol].

Kazuyoshi Ueta, Rika Nougawa, Masaru Amano, Takashi Mashimo, Osamu Nagata

Open publisher page 1 citations

Abstract

BACKGROUND: Individual variation in the sensitivity to anesthetics induces the delayed awakening and the severe postoperative pain at an inappropriate dose. We designed the study to see the correlation of the individual sensitivity to fentanyl and that to propofol which have different mechanism. METHODS: General anesthesia was induced using target controlled infusion system of fentanyl and propofol. Fentanyl effect-site concentration gradually increased towards a target plasma concentration of 3 ng x ml(-1) until the appearance of the subjective symptom such as dizziness, a sensation of warmth and other reactions. After this, propofol effect-site concentration gradually increased towards a target plasma concentration of 4 microg x ml(-1) until loss of consciousness (LOC). The effect-site concentrations of fentanyl at the symptom and propofol at loss of consciousness were measured. RESULTS: The correlation between the estimated effect-site concentration of fentanyl and propofol is not significant in the whole patient. However, a positive correlation between fentanyl and propofol was found in patients from 50s to 70s years of ages (r = 0.59). CONCLUSIONS: The correlation of the individual sensitivity to fentanyl and propofol was found in older age groups.

About this research paper

What this paper is about

BACKGROUND: Individual variation in the sensitivity to anesthetics induces the delayed awakening and the severe postoperative pain at an inappropriate dose. We designed the study to see the correlation of the individual sensitivity to fentanyl and that to propofol which have different mechanism. METHODS: General anesthesia was induced using target controlled infusion system of fentanyl and propofol. Fentanyl effect-site concentration gradually increased towards a target plasma concentration of 3 ng x ml(-1) until the appearance of the subjective symptom such as dizziness, a sensation of warmth and other reactions. After this, propofol effect-site concentration gradually increased towards a target plasma concentration of 4 microg x ml(-1) until loss of consciousness (LOC). The effect-site concentrations of fentanyl at the symptom and propofol at loss of consciousness were measured. RESULTS: The correlation between the estimated effect-site concentration of fentanyl and propofol is not significant in the whole patient. However, a positive correlation between fentanyl and propofol was found in patients from 50s to 70s years of ages (r = 0.59). CONCLUSIONS: The correlation of the individual sensitivity to fentanyl and propofol was found in older age groups.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Individual variation in the sensitivity to anesthetics induces the delayed awakening and the severe postoperative pain at an inappropriate dose. We designed the study to see the correlation of the individual sensitivity to fentanyl and that to propofol which have different mechanism. METHODS: General anesthesia was induced using target controlled infusion system of fentanyl and propofol. Fentanyl effect-site concentration gradually increased towards a target plasma concentration of 3 ng x ml(-1) until the appearance of the subjective symptom such as dizziness, a sensation of warmth and other reactions. After this, propofol effect-site concentration gradually increased towards a target plasma concentration of 4 microg x ml(-1) until loss of consciousness (LOC). The effect-site concentrations of fentanyl at the symptom and propofol at loss of consciousness were measured. RESULTS: The correlation between the estimated effect-site concentration of fentanyl and propofol is not significant in the whole patient. However, a positive correlation between fentanyl and propofol was found in patients from 50s to 70s years of ages (r = 0.59). CONCLUSIONS: The correlation of the individual sensitivity to fentanyl and propofol was found in older age groups.

Key concepts: Propofol, Fentanyl, Anesthesia, Medicine, Positive correlation, Plasma concentration, Correlation, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[The relationship of individual sensitivities to fentanyl and those to propofol]. — Research Paper | ScholarLens