Digital video subtraction angiography and duplex scanning in assessment of carotid artery disease: comparison with conventional angiography.
Eikelboom Bc, Ackerstaff Rg, Ludwig Jw, Moll Fl, de Vries Ar, Vermeulen Fe
Abstract
Eikelboom Bc, Ackerstaff Rg, Ludwig Jw, Moll Fl, de Vries Ar, Vermeulen Fe
Abstract
Digital video subtraction angiography (DVSA) and duplex scanning were compared to conventional angiography with regard to their accuracy in quantifying internal carotid artery disease. A classification of 108 carotid arteries available for comparison was made into five groups: normal (14), stenosis to 20% (15), stenosis from 20% to 49% (19), stenosis from 50% to 99% (44), and occlusion (16). The overall agreement corrected for chance (K) for DVSA was 0.738 +/- (SE) 0.049, which was better than for duplex scanning (K = 0.610 +/- 0.055). For hemodynamically significant disease (greater than or equal to 50% diameter reduction), both techniques were highly accurate: DVSA had a sensitivity of 95% (57/60) and a specificity of 92% (44/48); the sensitivity of duplex scanning was also 95% (57/60) and the specificity 85% (41/48). The accuracy in differentiating between high-grade stenosis and occlusion was 98% (59/60) for duplex scanning and 100% (60/60) for DVSA. The most prominent limitation of duplex scanning was its overestimation of disease in normal and minimally diseased arteries. Its specificity for ruling out any degree of disease was only 21% (3/14). DVSA had a poor predictive value of a normal test, 55% (12/22), and was more than one category wrong seven times, while this occurred only three times for duplex scanning. At the present time carotid endarterectomy without conventional angiography is only advocated when there is complete agreement between DVSA and duplex scanning.
OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Digital video subtraction angiography (DVSA) and duplex scanning were compared to conventional angiography with regard to their accuracy in quantifying internal carotid artery disease. A classification of 108 carotid arteries available for comparison was made into five groups: normal (14), stenosis to 20% (15), stenosis from 20% to 49% (19), stenosis from 50% to 99% (44), and occlusion (16). The overall agreement corrected for chance (K) for DVSA was 0.738 +/- (SE) 0.049, which was better than for duplex scanning (K = 0.610 +/- 0.055). For hemodynamically significant disease (greater than or equal to 50% diameter reduction), both techniques were highly accurate: DVSA had a sensitivity of 95% (57/60) and a specificity of 92% (44/48); the sensitivity of duplex scanning was also 95% (57/60) and the specificity 85% (41/48). The accuracy in differentiating between high-grade stenosis and occlusion was 98% (59/60) for duplex scanning and 100% (60/60) for DVSA. The most prominent limitation of duplex scanning was its overestimation of disease in normal and minimally diseased arteries. Its specificity for ruling out any degree of disease was only 21% (3/14). DVSA had a poor predictive value of a normal test, 55% (12/22), and was more than one category wrong seven times, while this occurred only three times for duplex scanning. At the present time carotid endarterectomy without conventional angiography is only advocated when there is complete agreement between DVSA and duplex scanning.
Key concepts: Duplex scanning, Medicine, Stenosis, Digital subtraction angiography, Radiology, Occlusion, Angiography, Carotid endarterectomy