Incomplete Oxidation of Ethylenediaminetetraacetic Acid in Chemical Oxygen Demand Analysis
James Edgar Anderson, Sherry A. Mueller, Byung R. Kim
Abstract
James Edgar Anderson, Sherry A. Mueller, Byung R. Kim
Abstract
Ethylenediaminetetraacetic acid (EDTA) was found to incompletely oxidize in chemical oxygen demand (COD) analysis, leading to incorrect COD values for water samples containing relatively large amounts of EDTA. The degree of oxidation depended on the oxidant used, its concentration, and the length of digestion. The COD concentrations measured using COD vials with a potassium dichromate concentration of 0.10 N (after dilution by sample and sulfuric acid) were near theoretical oxygen demand values. However, COD measured with dichromate concentrations of 0.010 N and 0.0022 N were 30 to 40% lower than theoretical oxygen demand values. Similarly, lower COD values were observed with manganic sulfate as oxidant at 0.011 N. Extended digestion yielded somewhat higher COD values, suggesting incomplete and slower oxidation of EDTA, as a result of lower oxidant concentrations. For wastewater in which EDTA is a large fraction of COD, accurate COD measurement may not be achieved with methods using dichromate concentrations less than 0.1 N.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Ethylenediaminetetraacetic acid (EDTA) was found to incompletely oxidize in chemical oxygen demand (COD) analysis, leading to incorrect COD values for water samples containing relatively large amounts of EDTA. The degree of oxidation depended on the oxidant used, its concentration, and the length of digestion. The COD concentrations measured using COD vials with a potassium dichromate concentration of 0.10 N (after dilution by sample and sulfuric acid) were near theoretical oxygen demand values. However, COD measured with dichromate concentrations of 0.010 N and 0.0022 N were 30 to 40% lower than theoretical oxygen demand values. Similarly, lower COD values were observed with manganic sulfate as oxidant at 0.011 N. Extended digestion yielded somewhat higher COD values, suggesting incomplete and slower oxidation of EDTA, as a result of lower oxidant concentrations. For wastewater in which EDTA is a large fraction of COD, accurate COD measurement may not be achieved with methods using dichromate concentrations less than 0.1 N.
Key concepts: Ethylenediaminetetraacetic acid, Chemical oxygen demand, Potassium dichromate, Chemistry, Sulfuric acid, Oxygen, Wastewater, Biochemical oxygen demand