1976PubMedRequires access

Protection of airline flight attendants from hypoxia following rapid decompression.

Busby De, Higgins Ea, Funkhouser Ge

Open publisher page 2 citations

Abstract

To determine the maximum time for working flight attendants to effectively initiate airline passenger mask donning after onset of a rapid, severe decompression, we exposed 10 subjects in two series of tests to a decompression from 6,500 to 34,000 ft (2,000 to 10,400 m) in 26 s, followed by descent at 5,000 ft/min (1,500 m/min) while subjects performed a light-to-moderate workload. Supplemental oxygen was provided in one series from a compressed oxygen system, and in the other series from a chemical oxygen generator system. With delays to mask doning of 10 and 15 s, no hypoxic effects occurred. With delays of 20 and 25 s, increasing hypoxic effects, similar in frequency for the two systems, occurred. Some technical problems in mask donning contributed to losses of consciousness with the latter two delays.

About this research paper

What this paper is about

To determine the maximum time for working flight attendants to effectively initiate airline passenger mask donning after onset of a rapid, severe decompression, we exposed 10 subjects in two series of tests to a decompression from 6,500 to 34,000 ft (2,000 to 10,400 m) in 26 s, followed by descent at 5,000 ft/min (1,500 m/min) while subjects performed a light-to-moderate workload. Supplemental oxygen was provided in one series from a compressed oxygen system, and in the other series from a chemical oxygen generator system. With delays to mask doning of 10 and 15 s, no hypoxic effects occurred. With delays of 20 and 25 s, increasing hypoxic effects, similar in frequency for the two systems, occurred. Some technical problems in mask donning contributed to losses of consciousness with the latter two delays.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To determine the maximum time for working flight attendants to effectively initiate airline passenger mask donning after onset of a rapid, severe decompression, we exposed 10 subjects in two series of tests to a decompression from 6,500 to 34,000 ft (2,000 to 10,400 m) in 26 s, followed by descent at 5,000 ft/min (1,500 m/min) while subjects performed a light-to-moderate workload. Supplemental oxygen was provided in one series from a compressed oxygen system, and in the other series from a chemical oxygen generator system. With delays to mask doning of 10 and 15 s, no hypoxic effects occurred. With delays of 20 and 25 s, increasing hypoxic effects, similar in frequency for the two systems, occurred. Some technical problems in mask donning contributed to losses of consciousness with the latter two delays.

Key concepts: Decompression, Decompression sickness, Descent (aeronautics), Hypoxia (environmental), Workload, Oxygen, Anesthesia, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Protection of airline flight attendants from hypoxia following rapid decompression. — Research Paper | ScholarLens