Measurement of Ambient Dose Equivalent and Directional Dose Equivalent in a 60Co Beam

A -M Perroche, M Boutillon

Open publisher page 1 citations

Abstract

An experimental determination is described of the ambient dose equivalent and directional dose equivalent at 1 g.cm-2 below the surface of the ICRU sphere, in the gamma radiation from 60Co. These quantities are related to exposure and kerma in air measured at the same point with an uncertainty not exceeding 0.3% for the ambient dose equivalent and 1% for the directional dose equivalent. A theoretical determination of these quantities has also been performed and gives values compatible with those obtained experimentally.

About this research paper

What this paper is about

An experimental determination is described of the ambient dose equivalent and directional dose equivalent at 1 g.cm-2 below the surface of the ICRU sphere, in the gamma radiation from 60Co. These quantities are related to exposure and kerma in air measured at the same point with an uncertainty not exceeding 0.3% for the ambient dose equivalent and 1% for the directional dose equivalent. A theoretical determination of these quantities has also been performed and gives values compatible with those obtained experimentally.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An experimental determination is described of the ambient dose equivalent and directional dose equivalent at 1 g.cm-2 below the surface of the ICRU sphere, in the gamma radiation from 60Co. These quantities are related to exposure and kerma in air measured at the same point with an uncertainty not exceeding 0.3% for the ambient dose equivalent and 1% for the directional dose equivalent. A theoretical determination of these quantities has also been performed and gives values compatible with those obtained experimentally.

Key concepts: Equivalent dose, Kerma, Percentage depth dose curve, Radiation, Beam (structure), Physics, Dosimetry, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of Ambient Dose Equivalent and Directional Dose Equivalent in a 60Co Beam — Research Paper | ScholarLens