1996PubMedRequires access

Reproducibility of color Doppler imaging in orbital vessels.

Brigitte Senn, Hedwig J. Kaiser, Andreas Schötzau, Josef Flammer

Open publisher page 37 citations

Abstract

The purpose of this study was to evaluate the short-term reproducibility, the long-term reproducibility, and the reproducibility of the measurements made between two different examiners of blood-flow velocity in extraocular vessels using color Doppler imaging (CDI). In a group of 10 healthy volunteers, measurements of the peak-systolic velocity (PSV), end-diastolic velocity (EDV), and resistivity index (RI) in the ophthalmic artery and the central retinal artery as well as one lateral and one medial short posterior ciliary artery were performed. The best intraindividual reproducibility, expressed as the relative error, was found for the PSV and RI measured in the ophthalmic artery (OA; PSV 5.9%, RI 3.1%) and the central retinal artery (CRA; PSV 7.7%, RI 4.7%). The PSV and RI determined in the posterior ciliary arteries were less reproducible but as much so as the EDV measured in the OA (11.8%) and CRA (19.9%). No systematic trend could be found between the first and second measurements. However, the long-term fluctuation was considerable high. Measurements of PSVs showed good concurrence between the two observers in all four vessels measured. The EDVs and RIs differed statistically significantly between the two observers. This difference was most pronounced in the posterior ciliary arteries.

About this research paper

What this paper is about

The purpose of this study was to evaluate the short-term reproducibility, the long-term reproducibility, and the reproducibility of the measurements made between two different examiners of blood-flow velocity in extraocular vessels using color Doppler imaging (CDI). In a group of 10 healthy volunteers, measurements of the peak-systolic velocity (PSV), end-diastolic velocity (EDV), and resistivity index (RI) in the ophthalmic artery and the central retinal artery as well as one lateral and one medial short posterior ciliary artery were performed. The best intraindividual reproducibility, expressed as the relative error, was found for the PSV and RI measured in the ophthalmic artery (OA; PSV 5.9%, RI 3.1%) and the central retinal artery (CRA; PSV 7.7%, RI 4.7%). The PSV and RI determined in the posterior ciliary arteries were less reproducible but as much so as the EDV measured in the OA (11.8%) and CRA (19.9%). No systematic trend could be found between the first and second measurements. However, the long-term fluctuation was considerable high. Measurements of PSVs showed good concurrence between the two observers in all four vessels measured. The EDVs and RIs differed statistically significantly between the two observers. This difference was most pronounced in the posterior ciliary arteries.

Why it matters

OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to evaluate the short-term reproducibility, the long-term reproducibility, and the reproducibility of the measurements made between two different examiners of blood-flow velocity in extraocular vessels using color Doppler imaging (CDI). In a group of 10 healthy volunteers, measurements of the peak-systolic velocity (PSV), end-diastolic velocity (EDV), and resistivity index (RI) in the ophthalmic artery and the central retinal artery as well as one lateral and one medial short posterior ciliary artery were performed. The best intraindividual reproducibility, expressed as the relative error, was found for the PSV and RI measured in the ophthalmic artery (OA; PSV 5.9%, RI 3.1%) and the central retinal artery (CRA; PSV 7.7%, RI 4.7%). The PSV and RI determined in the posterior ciliary arteries were less reproducible but as much so as the EDV measured in the OA (11.8%) and CRA (19.9%). No systematic trend could be found between the first and second measurements. However, the long-term fluctuation was considerable high. Measurements of PSVs showed good concurrence between the two observers in all four vessels measured. The EDVs and RIs differed statistically significantly between the two observers. This difference was most pronounced in the posterior ciliary arteries.

Key concepts: Reproducibility, Central retinal artery, Ophthalmic artery, Medicine, Diastole, Nuclear medicine, Blood flow, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Reproducibility of color Doppler imaging in orbital vessels. — Research Paper | ScholarLens