2016American Journal of Civil EngineeringOpen access

Application of Progressive Collapse Analysis in a High-Rise Frame-Core Tube Structure

Kai Hu

Open full text 0 citations

Abstract

Frame-core tube structure system is commonly adopted in high-rise office buildings and landmarks, which will cause a large range of damage and serious loss of life and property once the progressive collapse occurs. To analysis the progressive collapse resistance of a high-rise frame-core tube practical project, numerical simulation analysis based on alternate path method and explicit dynamics theory was conducted to study the dynamic response of the remain structure after removing a key member. In addition, large-scaled tests for the frame-core tube structure under static and dynamic loads were carried out to study the behavior and damage situation of the structure. The numerical simulation and test results proved that progressive collapse would not occur when local damages occurred in the bottom corner column, and the structure still has a good seismic performance under dynamic actions. And the feasibility and reliability of the selected numerical simulation method of progressive collapse analysis is proved according to the test results.

Open-access reader

About this research paper

What this paper is about

Frame-core tube structure system is commonly adopted in high-rise office buildings and landmarks, which will cause a large range of damage and serious loss of life and property once the progressive collapse occurs. To analysis the progressive collapse resistance of a high-rise frame-core tube practical project, numerical simulation analysis based on alternate path method and explicit dynamics theory was conducted to study the dynamic response of the remain structure after removing a key member. In addition, large-scaled tests for the frame-core tube structure under static and dynamic loads were carried out to study the behavior and damage situation of the structure. The numerical simulation and test results proved that progressive collapse would not occur when local damages occurred in the bottom corner column, and the structure still has a good seismic performance under dynamic actions. And the feasibility and reliability of the selected numerical simulation method of progressive collapse analysis is proved according to the test results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Frame-core tube structure system is commonly adopted in high-rise office buildings and landmarks, which will cause a large range of damage and serious loss of life and property once the progressive collapse occurs. To analysis the progressive collapse resistance of a high-rise frame-core tube practical project, numerical simulation analysis based on alternate path method and explicit dynamics theory was conducted to study the dynamic response of the remain structure after removing a key member. In addition, large-scaled tests for the frame-core tube structure under static and dynamic loads were carried out to study the behavior and damage situation of the structure. The numerical simulation and test results proved that progressive collapse would not occur when local damages occurred in the bottom corner column, and the structure still has a good seismic performance under dynamic actions. And the feasibility and reliability of the selected numerical simulation method of progressive collapse analysis is proved according to the test results.

Key concepts: Progressive collapse, Structural engineering, Frame (networking), Computer simulation, Core (optical fiber), Tube (container), Engineering, Simulation

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Progressive Collapse Analysis in a High-Rise Frame-Core Tube Structure — Research Paper | ScholarLens