1987•American Journal of Physiology-Endocrinology and MetabolismRequires access

Periodic interactions of GH-releasing factor and somatostatin can augment GH release in vitro

Jeffrey M Weiss, Michael John Cronin, Michael O. Thorner

Open publisher page 34 citations

Abstract

Growth hormone (GH) is secreted as pulses in vivo. To understand the signals governing this periodicity, we have established a perifusion-based model of pulsatile GH release. Male rat anterior pituitaries were dispersed and perifused with pulses of human growth hormone-releasing factor-(1--40) (GHRF), with or without a continuous or discontinuous somatostatin tonus. An experiment was composed of a 1-h base-line collection followed by four 3-h cycles; each contained single or paired 10-min infusion(s) of 3 nM GHRF. In testing the impact of somatostatin, the protocol was identical except that 0.3 nM somatostatin was added 30 min into the base-line period and then was either continued throughout the study or withdrawn during the periods of GHRF infusion. GH base lines with somatostatin were lower than vehicle base lines (P less than 0.05). GHRF pulses generated consistent peaks of GH release between 200 and 300 ng. min-1. (10(7) cells)-1, and these peaks were not altered by continuous somatostatin. In contrast, withdrawal of somatostatin during GHRF administration elicited markedly higher GH peaks (P less than 0.05) and more total GH release (P less than 0.05). This response could not be accounted for by the additive effects of GHRF and somatostatin withdrawal.

About this research paper

What this paper is about

Growth hormone (GH) is secreted as pulses in vivo. To understand the signals governing this periodicity, we have established a perifusion-based model of pulsatile GH release. Male rat anterior pituitaries were dispersed and perifused with pulses of human growth hormone-releasing factor-(1--40) (GHRF), with or without a continuous or discontinuous somatostatin tonus. An experiment was composed of a 1-h base-line collection followed by four 3-h cycles; each contained single or paired 10-min infusion(s) of 3 nM GHRF. In testing the impact of somatostatin, the protocol was identical except that 0.3 nM somatostatin was added 30 min into the base-line period and then was either continued throughout the study or withdrawn during the periods of GHRF infusion. GH base lines with somatostatin were lower than vehicle base lines (P less than 0.05). GHRF pulses generated consistent peaks of GH release between 200 and 300 ng. min-1. (10(7) cells)-1, and these peaks were not altered by continuous somatostatin. In contrast, withdrawal of somatostatin during GHRF administration elicited markedly higher GH peaks (P less than 0.05) and more total GH release (P less than 0.05). This response could not be accounted for by the additive effects of GHRF and somatostatin withdrawal.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Growth hormone (GH) is secreted as pulses in vivo. To understand the signals governing this periodicity, we have established a perifusion-based model of pulsatile GH release. Male rat anterior pituitaries were dispersed and perifused with pulses of human growth hormone-releasing factor-(1--40) (GHRF), with or without a continuous or discontinuous somatostatin tonus. An experiment was composed of a 1-h base-line collection followed by four 3-h cycles; each contained single or paired 10-min infusion(s) of 3 nM GHRF. In testing the impact of somatostatin, the protocol was identical except that 0.3 nM somatostatin was added 30 min into the base-line period and then was either continued throughout the study or withdrawn during the periods of GHRF infusion. GH base lines with somatostatin were lower than vehicle base lines (P less than 0.05). GHRF pulses generated consistent peaks of GH release between 200 and 300 ng. min-1. (10(7) cells)-1, and these peaks were not altered by continuous somatostatin. In contrast, withdrawal of somatostatin during GHRF administration elicited markedly higher GH peaks (P less than 0.05) and more total GH release (P less than 0.05). This response could not be accounted for by the additive effects of GHRF and somatostatin withdrawal.

Key concepts: Somatostatin, Endocrinology, Internal medicine, Growth hormone–releasing hormone, Pulsatile flow, In vivo, Peptide hormone, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Periodic interactions of GH-releasing factor and somatostatin can augment GH release in vitro — Research Paper | ScholarLens