2004RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden VerfahrenRequires access

Niedrigdosis-Spiral-CT des Thorax in der Verlaufskontrolle nichtmaligner Lungenerkrankungen

Eva Coppenrath, Ullrich G. Müeller-Lisse, Ursula Lechel, Richard R. Veit, Christian Weber, S. Banac, Roger Eibel, H. Bitterling, C. De Lorenzo, R. Fischer, Thomas Meindl, Maximilian F. Reiser

Open publisher page 7 citations

Abstract

PURPOSE: To assess image quality of chest CT with an 80 to 90 percent dose reduction in follow-up studies of patients with lung disease, dose and image quality of a low-dose protocol was investigated. MATERIALS AND METHODS: A follow-up low-dose CT (ND-CT, 120 kV, 10 mAs/slice, 3 mm slice thickness) was performed on 35 patients with non-malignant lung disease and compared with the initial standard dose CT (= SD-CT, 100 mAs/slice, 3 or 5 mm slice thickness). The dose was measured by thermo-luminescence in an Alderson phantom. Image quality was assessed by four independent radiologists in six perihilar, central and peripheral lung regions using a 4-point-scale ("very good", "good", "moderate", and "poor"). RESULTS: Effective dose was 0.5 mSv for ND-CT and 4.0 - 5.0 mSv for SD-CT. The ratings "very good"/"good" were given in the perihilar regions in ND-CT 97.5 % versus SD-CT 99.3 % (n. s.), in the central regions in ND-CT 96.4 % versus SD-CT 94.6 % (n. s.), and in the peripheral regions in ND-CT 70.0 % versus SD-CT 88.2 % (p < 0.01). CONCLUSION: Follow-up CT of pulmonary structures in patients with chronic lung disease can be performed with substantial dose reduction. A decrease of image quality may result in peripheral lung regions.

About this research paper

What this paper is about

PURPOSE: To assess image quality of chest CT with an 80 to 90 percent dose reduction in follow-up studies of patients with lung disease, dose and image quality of a low-dose protocol was investigated. MATERIALS AND METHODS: A follow-up low-dose CT (ND-CT, 120 kV, 10 mAs/slice, 3 mm slice thickness) was performed on 35 patients with non-malignant lung disease and compared with the initial standard dose CT (= SD-CT, 100 mAs/slice, 3 or 5 mm slice thickness). The dose was measured by thermo-luminescence in an Alderson phantom. Image quality was assessed by four independent radiologists in six perihilar, central and peripheral lung regions using a 4-point-scale ("very good", "good", "moderate", and "poor"). RESULTS: Effective dose was 0.5 mSv for ND-CT and 4.0 - 5.0 mSv for SD-CT. The ratings "very good"/"good" were given in the perihilar regions in ND-CT 97.5 % versus SD-CT 99.3 % (n. s.), in the central regions in ND-CT 96.4 % versus SD-CT 94.6 % (n. s.), and in the peripheral regions in ND-CT 70.0 % versus SD-CT 88.2 % (p < 0.01). CONCLUSION: Follow-up CT of pulmonary structures in patients with chronic lung disease can be performed with substantial dose reduction. A decrease of image quality may result in peripheral lung regions.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess image quality of chest CT with an 80 to 90 percent dose reduction in follow-up studies of patients with lung disease, dose and image quality of a low-dose protocol was investigated. MATERIALS AND METHODS: A follow-up low-dose CT (ND-CT, 120 kV, 10 mAs/slice, 3 mm slice thickness) was performed on 35 patients with non-malignant lung disease and compared with the initial standard dose CT (= SD-CT, 100 mAs/slice, 3 or 5 mm slice thickness). The dose was measured by thermo-luminescence in an Alderson phantom. Image quality was assessed by four independent radiologists in six perihilar, central and peripheral lung regions using a 4-point-scale ("very good", "good", "moderate", and "poor"). RESULTS: Effective dose was 0.5 mSv for ND-CT and 4.0 - 5.0 mSv for SD-CT. The ratings "very good"/"good" were given in the perihilar regions in ND-CT 97.5 % versus SD-CT 99.3 % (n. s.), in the central regions in ND-CT 96.4 % versus SD-CT 94.6 % (n. s.), and in the peripheral regions in ND-CT 70.0 % versus SD-CT 88.2 % (p < 0.01). CONCLUSION: Follow-up CT of pulmonary structures in patients with chronic lung disease can be performed with substantial dose reduction. A decrease of image quality may result in peripheral lung regions.

Key concepts: Medicine, Nuclear medicine, Lung, Image quality, Imaging phantom, Thorax (insect anatomy), Radiology, Effective dose (radiation)

Related papers

Back to paper searchBrowse research topicsOriginal source
Niedrigdosis-Spiral-CT des Thorax in der Verlaufskontrolle nichtmaligner Lungenerkrankungen — Research Paper | ScholarLens