2010•PubMedRequires access

[Determination of two bio-active compounds in Campylotropis hirtella (Franch.) Schindl. using reversed-phase high performance liquid chromatography].

Qing Tan, Qingyao Shou, Sheng Zhang, Zhengwu Shen

Open publisher page 2 citations

Abstract

A method of reversed-phase high performance liquid chromatography (RP-HPLC) using diode array detection (DAD) was developed for the quantitative determination of 3'-geranyl-5,7,4'-trihydroxyisoflavone (compound 1) and 8,9-dihydroxy-1-methoxy-[6',6'-dimethylpyrano(2',3': 2,3)]pterocarpene (compound 2) in Campylotropis hirtella. The separation and quantification were achieved using an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm), and mobile phases of acetonitrile and 0. 1% formic acid with gradient elution at a flow rate of 1.0 mL/min and 30 degrees C. The calibration curves for compounds 1 and 2 were linear in the ranges of 4.4-13.2 microg and 0.428-1.284 microg, respectively. The recoveries were 99.65% and 99.11% with the relative standard deviations of 1.83% and 2.59% (n=5), respectively. This RP-HPLC-DAD method is rather simple, accurate and convenient. It can be used for the quantitative determination of the active flavonoids in Campylotropis hirtella (Franch.) Schindl.

About this research paper

What this paper is about

A method of reversed-phase high performance liquid chromatography (RP-HPLC) using diode array detection (DAD) was developed for the quantitative determination of 3'-geranyl-5,7,4'-trihydroxyisoflavone (compound 1) and 8,9-dihydroxy-1-methoxy-[6',6'-dimethylpyrano(2',3': 2,3)]pterocarpene (compound 2) in Campylotropis hirtella. The separation and quantification were achieved using an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm), and mobile phases of acetonitrile and 0. 1% formic acid with gradient elution at a flow rate of 1.0 mL/min and 30 degrees C. The calibration curves for compounds 1 and 2 were linear in the ranges of 4.4-13.2 microg and 0.428-1.284 microg, respectively. The recoveries were 99.65% and 99.11% with the relative standard deviations of 1.83% and 2.59% (n=5), respectively. This RP-HPLC-DAD method is rather simple, accurate and convenient. It can be used for the quantitative determination of the active flavonoids in Campylotropis hirtella (Franch.) Schindl.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method of reversed-phase high performance liquid chromatography (RP-HPLC) using diode array detection (DAD) was developed for the quantitative determination of 3'-geranyl-5,7,4'-trihydroxyisoflavone (compound 1) and 8,9-dihydroxy-1-methoxy-[6',6'-dimethylpyrano(2',3': 2,3)]pterocarpene (compound 2) in Campylotropis hirtella. The separation and quantification were achieved using an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm), and mobile phases of acetonitrile and 0. 1% formic acid with gradient elution at a flow rate of 1.0 mL/min and 30 degrees C. The calibration curves for compounds 1 and 2 were linear in the ranges of 4.4-13.2 microg and 0.428-1.284 microg, respectively. The recoveries were 99.65% and 99.11% with the relative standard deviations of 1.83% and 2.59% (n=5), respectively. This RP-HPLC-DAD method is rather simple, accurate and convenient. It can be used for the quantitative determination of the active flavonoids in Campylotropis hirtella (Franch.) Schindl.

Key concepts: Chemistry, Chromatography, Formic acid, High-performance liquid chromatography, Acetonitrile, Calibration curve, Gradient elution, Resolution (logic)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of two bio-active compounds in Campylotropis hirtella (Franch.) Schindl. using reversed-phase high performance liquid chromatography]. — Research Paper | ScholarLens