A method of reversed-phase high performance liquid chromatography (RP-HPLC) using diode array detection (DAD) was developed for the quantitative determination of 3'-geranyl-5,7,4'-trihydroxyisoflavone (compound 1) and 8,9-dihydroxy-1-methoxy-[6',6'-dimethylpyrano(2',3': 2,3)]pterocarpene (compound 2) in Campylotropis hirtella. The separation and quantification were achieved using an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm), and mobile phases of acetonitrile and 0. 1% formic acid with gradient elution at a flow rate of 1.0 mL/min and 30 degrees C. The calibration curves for compounds 1 and 2 were linear in the ranges of 4.4-13.2 microg and 0.428-1.284 microg, respectively. The recoveries were 99.65% and 99.11% with the relative standard deviations of 1.83% and 2.59% (n=5), respectively. This RP-HPLC-DAD method is rather simple, accurate and convenient. It can be used for the quantitative determination of the active flavonoids in Campylotropis hirtella (Franch.) Schindl.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method of reversed-phase high performance liquid chromatography (RP-HPLC) using diode array detection (DAD) was developed for the quantitative determination of 3'-geranyl-5,7,4'-trihydroxyisoflavone (compound 1) and 8,9-dihydroxy-1-methoxy-[6',6'-dimethylpyrano(2',3': 2,3)]pterocarpene (compound 2) in Campylotropis hirtella. The separation and quantification were achieved using an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm), and mobile phases of acetonitrile and 0. 1% formic acid with gradient elution at a flow rate of 1.0 mL/min and 30 degrees C. The calibration curves for compounds 1 and 2 were linear in the ranges of 4.4-13.2 microg and 0.428-1.284 microg, respectively. The recoveries were 99.65% and 99.11% with the relative standard deviations of 1.83% and 2.59% (n=5), respectively. This RP-HPLC-DAD method is rather simple, accurate and convenient. It can be used for the quantitative determination of the active flavonoids in Campylotropis hirtella (Franch.) Schindl.