[Change of platelet count and P-selectin in preserved platelet concentrates].
Huifang Nie, Bao-Qing Lui, Run-Ling Zhang, Yuchun Zhang, Zhifeng Zhang, Chun-Fang Yuan
Abstract
Huifang Nie, Bao-Qing Lui, Run-Ling Zhang, Yuchun Zhang, Zhifeng Zhang, Chun-Fang Yuan
Abstract
To observe the change of quantity and quality of platelets preserved in a full-sealed bag, and explore the difference of platelets preserved in oscillating and static conditions at (22 +/- 2) degrees C, the platelet concentrates were prepared with a CS-3000-plus blood cell separator, the platelet counts were performed with automatic blood cell analyzer and P-selectin in supernatant of platelet concentrates was detected by ELISA. The results showed that both of platelet count and P-selectin content in the platelet concentrates had no significant difference between oscillating and static preservation condition. With prolongation of preserved time, the platelet count decreased and P-selectin content increased gradually in both preserved conditions. There was no difference in the platelet counts during 0 - 72 hours preservation in both conditions, and significant difference was seen in 96 - 120 hours preservation. It was concluded that the expired date for platelet product preserved in CS-3000-plus blood cell separator full-sealed system should be 3 days. Under the condition of (22 +/- 2) degrees C, the quality of the platelet preserved in oscillating state is not superior to static preservation.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
To observe the change of quantity and quality of platelets preserved in a full-sealed bag, and explore the difference of platelets preserved in oscillating and static conditions at (22 +/- 2) degrees C, the platelet concentrates were prepared with a CS-3000-plus blood cell separator, the platelet counts were performed with automatic blood cell analyzer and P-selectin in supernatant of platelet concentrates was detected by ELISA. The results showed that both of platelet count and P-selectin content in the platelet concentrates had no significant difference between oscillating and static preservation condition. With prolongation of preserved time, the platelet count decreased and P-selectin content increased gradually in both preserved conditions. There was no difference in the platelet counts during 0 - 72 hours preservation in both conditions, and significant difference was seen in 96 - 120 hours preservation. It was concluded that the expired date for platelet product preserved in CS-3000-plus blood cell separator full-sealed system should be 3 days. Under the condition of (22 +/- 2) degrees C, the quality of the platelet preserved in oscillating state is not superior to static preservation.
Key concepts: Platelet, Significant difference, P-selectin, Chemistry, Plateletpheresis, Blood cell, Separator (oil production), Platelet concentrate