National Dam Safety Program. Hermit Hollow Lake Dam (MO 31054), Mississippi - Kaskaskia - St. Louis Basin, Franklin County, Missouri. Phase I Inspection Report.

Steven Brady, Gene Wertepny, Tom Beckley, Dave Daniels

Open publisher page 0 citations

Abstract

Hermit Hollow Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will pass 33 percent of the Probable Maximum Flood without overtopping. The Probable Maximum Flood is defined as the flood discharge that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region. The guidelines require that a dam of small size with a high downstream hazard potential pass 50 to 100 percent of the PMF. Considering this dam's small size and low storage capacity, 50 percent of the PMF has been determined to be the appropriate spillway design flood. The 100-year frequency flood will not overtop the dam. The 100-year flood is one that has a 1 percent chance of being exceeded in any given year.

About this research paper

What this paper is about

Hermit Hollow Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will pass 33 percent of the Probable Maximum Flood without overtopping. The Probable Maximum Flood is defined as the flood discharge that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region. The guidelines require that a dam of small size with a high downstream hazard potential pass 50 to 100 percent of the PMF. Considering this dam's small size and low storage capacity, 50 percent of the PMF has been determined to be the appropriate spillway design flood. The 100-year frequency flood will not overtop the dam. The 100-year flood is one that has a 1 percent chance of being exceeded in any given year.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hermit Hollow Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the guidelines for a dam having the above size and hazard potential. The spillway will pass 33 percent of the Probable Maximum Flood without overtopping. The Probable Maximum Flood is defined as the flood discharge that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region. The guidelines require that a dam of small size with a high downstream hazard potential pass 50 to 100 percent of the PMF. Considering this dam's small size and low storage capacity, 50 percent of the PMF has been determined to be the appropriate spillway design flood. The 100-year frequency flood will not overtop the dam. The 100-year flood is one that has a 1 percent chance of being exceeded in any given year.

Key concepts: Spillway, Detention basin, Flood myth, Hydrology (agriculture), Environmental science, Hazard, Dam failure, St louis

Related papers

Back to paper searchBrowse research topicsOriginal source
National Dam Safety Program. Hermit Hollow Lake Dam (MO 31054), Mississippi - Kaskaskia - St. Louis Basin, Franklin County, Missouri. Phase I Inspection Report. — Research Paper | ScholarLens