Research of Current-Limiting Effect of Transformer-Based Fault Current Limiters

Chen Li

Open publisher page 0 citations

Abstract

This paper introduces the basic principle of transformer fault current limiter that is composed of a capacitor in parallel with primary side of a transformer, whose second side is connected to a discharge gap. The current limiting effect is described quantitatively by analyzing the steady-state characteristics while the fault current limiter is limiting short-circuit current. The application of the fault current limiter in a 500 kV power system is simulated with PSCAD software which can create the equivalent simulation model. To verify the current-limiting effect of the fault current limiter, a practical short-circuit test circuit is given. The short-circuit test is programmed respectively based on the circuit with and without the fault current limiter. Meanwhile, by simulating short-circuit of a test circuit with PSCAD software, the waveforms of the short-circuit current will be accessed. The experimental results and simulation results show that the transformer-based fault current limiter has a good effect on limiting short-circuits current and can be used as an effective protector for restraining the short-circuit current in power systems.

About this research paper

What this paper is about

This paper introduces the basic principle of transformer fault current limiter that is composed of a capacitor in parallel with primary side of a transformer, whose second side is connected to a discharge gap. The current limiting effect is described quantitatively by analyzing the steady-state characteristics while the fault current limiter is limiting short-circuit current. The application of the fault current limiter in a 500 kV power system is simulated with PSCAD software which can create the equivalent simulation model. To verify the current-limiting effect of the fault current limiter, a practical short-circuit test circuit is given. The short-circuit test is programmed respectively based on the circuit with and without the fault current limiter. Meanwhile, by simulating short-circuit of a test circuit with PSCAD software, the waveforms of the short-circuit current will be accessed. The experimental results and simulation results show that the transformer-based fault current limiter has a good effect on limiting short-circuits current and can be used as an effective protector for restraining the short-circuit current in power systems.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper introduces the basic principle of transformer fault current limiter that is composed of a capacitor in parallel with primary side of a transformer, whose second side is connected to a discharge gap. The current limiting effect is described quantitatively by analyzing the steady-state characteristics while the fault current limiter is limiting short-circuit current. The application of the fault current limiter in a 500 kV power system is simulated with PSCAD software which can create the equivalent simulation model. To verify the current-limiting effect of the fault current limiter, a practical short-circuit test circuit is given. The short-circuit test is programmed respectively based on the circuit with and without the fault current limiter. Meanwhile, by simulating short-circuit of a test circuit with PSCAD software, the waveforms of the short-circuit current will be accessed. The experimental results and simulation results show that the transformer-based fault current limiter has a good effect on limiting short-circuits current and can be used as an effective protector for restraining the short-circuit current in power systems.

Key concepts: Fault current limiter, Current limiting, Short circuit, Limiter, Transformer, Electrical engineering, Engineering, Electronic circuit

Related papers

Back to paper searchBrowse research topicsOriginal source
Research of Current-Limiting Effect of Transformer-Based Fault Current Limiters — Research Paper | ScholarLens