2009Unpublished venueRequires access

Research on the Alternatives of Non-ammonia Water in Determination of Total Nitrogen in Water Quality Analysis

Nian Yu

Open publisher page 0 citations

Abstract

According to the regulation GB/T 11894-89,non-ammonia water must be used throughout the determination of total nitrogen in water qauality analysis.The preparation of non-ammonia water,however,needs a lot of time,labor and money,so the non-ammonia water is not suitable for the determination of lots of samples.Ammonia ISM is used to measure the concentration of ammonia in distilled water,newly prepared double distilled water and non-ammonia water;the result shows that the ammonia concentration in newly prepared double distilled water is relatively low(0.80mg/L),and it is close to that of non-ammonia water(0.70~0.90mg/L).They find that the blank experiment (A ≤0.030),standard curve(R2=0.9987),accuracy and preciseness all meet the needs in standard and sample determination while following the GB standard.The results indicate that this method has its value in application.

About this research paper

What this paper is about

According to the regulation GB/T 11894-89,non-ammonia water must be used throughout the determination of total nitrogen in water qauality analysis.The preparation of non-ammonia water,however,needs a lot of time,labor and money,so the non-ammonia water is not suitable for the determination of lots of samples.Ammonia ISM is used to measure the concentration of ammonia in distilled water,newly prepared double distilled water and non-ammonia water;the result shows that the ammonia concentration in newly prepared double distilled water is relatively low(0.80mg/L),and it is close to that of non-ammonia water(0.70~0.90mg/L).They find that the blank experiment (A ≤0.030),standard curve(R2=0.9987),accuracy and preciseness all meet the needs in standard and sample determination while following the GB standard.The results indicate that this method has its value in application.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

According to the regulation GB/T 11894-89,non-ammonia water must be used throughout the determination of total nitrogen in water qauality analysis.The preparation of non-ammonia water,however,needs a lot of time,labor and money,so the non-ammonia water is not suitable for the determination of lots of samples.Ammonia ISM is used to measure the concentration of ammonia in distilled water,newly prepared double distilled water and non-ammonia water;the result shows that the ammonia concentration in newly prepared double distilled water is relatively low(0.80mg/L),and it is close to that of non-ammonia water(0.70~0.90mg/L).They find that the blank experiment (A ≤0.030),standard curve(R2=0.9987),accuracy and preciseness all meet the needs in standard and sample determination while following the GB standard.The results indicate that this method has its value in application.

Key concepts: Distilled water, Ammonia, Water quality, Nitrogen, Standard solution, Chemistry, Environmental science, Chromatography

Related papers