Correlation between the thresholds acquired with ASSR and pure tone audiometry
Sun Yan
Abstract
Sun Yan
Abstract
Objective: To determine the threshhold of multiple auditory steadystate responses(ASSR) and pure tone audiometry in children aged five to ten with normal hearing,and to explore the correlation between them.Methods: Thirty children with normal hearing had the ASSR and pure tone audiometry determined at 0.25,0.5,1,2,4 and 8 kHz.The coherence and correlation between the two groups were determined by the t test and the correlated modulus t test.Results: The different average threshholds of ASSR and pure tone audiometry at all tested frequencies ranged from 11 to 16.50 dBHL.There was a statistical difference between the result obtained by ASSR and pure tone audiometry at all tested frequencies(P0.05),especially at 0.25kHz and 0.5kHz(P0.01).The correlation was significant between the results by ASSR and pure tone audiometry at all tested frequencies(P0.05) by using the correlated modulus t test,except for 0.25kHz and 0.5kHz(P0.05).The correlation was obvious with an increase of frequency.Conclusion:Inthe middle or high frequencies,there are good correlations between ASSRand pure tone audiometry.However,there is a numerical value betweenthem.It is feasible to confer the pure tone hearingthreshhold of childrenagedfromfive toten by determiningthe threshhold of ASSRand by usingthe numerical value.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To determine the threshhold of multiple auditory steadystate responses(ASSR) and pure tone audiometry in children aged five to ten with normal hearing,and to explore the correlation between them.Methods: Thirty children with normal hearing had the ASSR and pure tone audiometry determined at 0.25,0.5,1,2,4 and 8 kHz.The coherence and correlation between the two groups were determined by the t test and the correlated modulus t test.Results: The different average threshholds of ASSR and pure tone audiometry at all tested frequencies ranged from 11 to 16.50 dBHL.There was a statistical difference between the result obtained by ASSR and pure tone audiometry at all tested frequencies(P0.05),especially at 0.25kHz and 0.5kHz(P0.01).The correlation was significant between the results by ASSR and pure tone audiometry at all tested frequencies(P0.05) by using the correlated modulus t test,except for 0.25kHz and 0.5kHz(P0.05).The correlation was obvious with an increase of frequency.Conclusion:Inthe middle or high frequencies,there are good correlations between ASSRand pure tone audiometry.However,there is a numerical value betweenthem.It is feasible to confer the pure tone hearingthreshhold of childrenagedfromfive toten by determiningthe threshhold of ASSRand by usingthe numerical value.
Key concepts: Pure tone audiometry, Audiology, Audiometry, Medicine, Correlation, Tone (literature), Pure tone, Positive correlation