2013•Zhiye yu jiankangRequires access

Determination of lead in urine by GFAAS with molybdenum-coated graphite tube

Rong Chen

Open publisher page 0 citations

Abstract

[Objective]To establish a simple and fast and practical method for determination of urinary lead.[Methods]Urine was diluted by using mixed matrix modifier,then directly molybdenum-coated pyrolytic graphite tube graphite furnace atomic absorption spectrometry method(GFAAS) was adopted for the determination of lead content.[Results] The urinary lead content was linear in the range of 0-100 μg/L,and the correlation coefficient was 0.998.The relative standard deviation(RSD) was 0.314%-1.447%.The detection limit was 5 μg/L,recoveries were 98.07%-111.5%.[Conclusion]The method is simple and rapid,accurate and reliable,with safe environmental protection,and suitable for the determination of lead in urine.

About this research paper

What this paper is about

[Objective]To establish a simple and fast and practical method for determination of urinary lead.[Methods]Urine was diluted by using mixed matrix modifier,then directly molybdenum-coated pyrolytic graphite tube graphite furnace atomic absorption spectrometry method(GFAAS) was adopted for the determination of lead content.[Results] The urinary lead content was linear in the range of 0-100 μg/L,and the correlation coefficient was 0.998.The relative standard deviation(RSD) was 0.314%-1.447%.The detection limit was 5 μg/L,recoveries were 98.07%-111.5%.[Conclusion]The method is simple and rapid,accurate and reliable,with safe environmental protection,and suitable for the determination of lead in urine.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To establish a simple and fast and practical method for determination of urinary lead.[Methods]Urine was diluted by using mixed matrix modifier,then directly molybdenum-coated pyrolytic graphite tube graphite furnace atomic absorption spectrometry method(GFAAS) was adopted for the determination of lead content.[Results] The urinary lead content was linear in the range of 0-100 μg/L,and the correlation coefficient was 0.998.The relative standard deviation(RSD) was 0.314%-1.447%.The detection limit was 5 μg/L,recoveries were 98.07%-111.5%.[Conclusion]The method is simple and rapid,accurate and reliable,with safe environmental protection,and suitable for the determination of lead in urine.

Key concepts: Graphite furnace atomic absorption, Detection limit, Pyrolytic carbon, Graphite, Relative standard deviation, Urine, Chemistry, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of lead in urine by GFAAS with molybdenum-coated graphite tube — Research Paper | ScholarLens