2008Power System Protection and ControlOpen access

Discussion on the main transformer protection starting the failure of current circuit

YE Wen-de

Open full text 0 citations

Abstract

This paper starts malfunctioning transformer protection to the current criterion for research orientation of the object,for example of the method of transformers in different locations in the vicinity of the short-circuit fault,the use of CT transformer bushing of the current transformer protection as the start of the current failure criteria for the practice of protection may lead to miss trip or maloperation for the design department and the peer experts to discuss.Finally,at the actual CT secondary windings,this paper proposes rectification to achieve the purpose of regulating circuit wiring.

About this research paper

What this paper is about

This paper starts malfunctioning transformer protection to the current criterion for research orientation of the object,for example of the method of transformers in different locations in the vicinity of the short-circuit fault,the use of CT transformer bushing of the current transformer protection as the start of the current failure criteria for the practice of protection may lead to miss trip or maloperation for the design department and the peer experts to discuss.Finally,at the actual CT secondary windings,this paper proposes rectification to achieve the purpose of regulating circuit wiring.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper starts malfunctioning transformer protection to the current criterion for research orientation of the object,for example of the method of transformers in different locations in the vicinity of the short-circuit fault,the use of CT transformer bushing of the current transformer protection as the start of the current failure criteria for the practice of protection may lead to miss trip or maloperation for the design department and the peer experts to discuss.Finally,at the actual CT secondary windings,this paper proposes rectification to achieve the purpose of regulating circuit wiring.

Key concepts: Transformer, Bushing, Current transformer, Electromagnetic coil, Electrical engineering, Engineering, Rectification, Short circuit