2010Unpublished venueRequires access

Determination of Cobalt in Surface Water and Wastewater by FAAS

HE Feng-yan

Open publisher page 0 citations

Abstract

This article explored the cobalt determination method from surface water and wastewater through a series of tests in terms of sample pre-treatment,instruments condition optimization,and detection limit,RSD,accuracy and recovery rate.In our test,the detection limit is 0.01 mg/L,the RSD is 0.6%~16%,the accurancy rate is-0.3%(1.01±0.05 μg/mL) and the recovery rate is 90%~104%,the method satisfies the demands from environmental monitoring technology standard,the environment management and environmental assessment system.We suggest that it will make this a corresponding standard by Government.

About this research paper

What this paper is about

This article explored the cobalt determination method from surface water and wastewater through a series of tests in terms of sample pre-treatment,instruments condition optimization,and detection limit,RSD,accuracy and recovery rate.In our test,the detection limit is 0.01 mg/L,the RSD is 0.6%~16%,the accurancy rate is-0.3%(1.01±0.05 μg/mL) and the recovery rate is 90%~104%,the method satisfies the demands from environmental monitoring technology standard,the environment management and environmental assessment system.We suggest that it will make this a corresponding standard by Government.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article explored the cobalt determination method from surface water and wastewater through a series of tests in terms of sample pre-treatment,instruments condition optimization,and detection limit,RSD,accuracy and recovery rate.In our test,the detection limit is 0.01 mg/L,the RSD is 0.6%~16%,the accurancy rate is-0.3%(1.01±0.05 μg/mL) and the recovery rate is 90%~104%,the method satisfies the demands from environmental monitoring technology standard,the environment management and environmental assessment system.We suggest that it will make this a corresponding standard by Government.

Key concepts: Wastewater, Detection limit, Surface water, Recovery rate, Cobalt, Environmental science, Limit (mathematics), Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Cobalt in Surface Water and Wastewater by FAAS — Research Paper | ScholarLens