Determination of aluminum content in dairy products-Inductively Coupled Plasma Mass Spectrometry(ICP-MS)
Jindou Jiang
Abstract
Jindou Jiang
Abstract
The optimization of sample preparation method,the use of indium as internal standard materials ICP-MS determination of aluminum content in dairy products is related to aluminum concentration in the range of 0~160 ng/mL;the regression equation was Y = 0.0693X +0.0125;correlation coefficient of r = 0.9999;recovery ranged from 92.4 to 104.5%,average of 96.7%;sample RSD 6.0%.The method detection limit was 0.1 mg/kg.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The optimization of sample preparation method,the use of indium as internal standard materials ICP-MS determination of aluminum content in dairy products is related to aluminum concentration in the range of 0~160 ng/mL;the regression equation was Y = 0.0693X +0.0125;correlation coefficient of r = 0.9999;recovery ranged from 92.4 to 104.5%,average of 96.7%;sample RSD 6.0%.The method detection limit was 0.1 mg/kg.
Key concepts: Inductively coupled plasma mass spectrometry, Chemistry, Detection limit, Chromatography, Analytical Chemistry (journal), Mass spectrometry, Correlation coefficient, Inductively coupled plasma