2012Zhongguo yixue yingxiangxue zazhiRequires access

Comparison of Dog Renal Artery Imaging with Multi-slice CT Using Different Doses Contrast Media

Xiaolong Li

Open publisher page 0 citations

Abstract

Purpose To investigate the feasibility of dog renal artery imaging with multi-slice CT (MSCT) using different doses contrast media. Materials and Methods Six dogs were selected and randomly divided into three groups using different doses contrast agent, Iohexol, at 1.62, 2.02, 2.40ml/kg, respectively. Each dosage group was repeated three times with at least 48 hours scan interval. Imaging quality of renal parenchymal, renal artery and visualization of renal artery branches were graded on axial and post-processed views. The CT values of main renal artery and branches as well as signal-to-noise ratio in abdominal aorta were measured. Results There was no statistical difference in renal parenchymal imaging among the three groups (P0.05). Main renal artery and its 3rd-order branches were clearly shown in all three groups without statistical difference in scoring (P 0.05). There was no statistical difference in comparing CT values in different portions in main renal artery and its 3rd-order branches (P 0.05). There was no statistical difference in signal-to-noise ratio within abdominal aorta among all groups (P0.05). Conclusion High quality images can be obtained in imaging dog renal arteries with MSCT using low dose contrast media of 1.62ml/kg.

About this research paper

What this paper is about

Purpose To investigate the feasibility of dog renal artery imaging with multi-slice CT (MSCT) using different doses contrast media. Materials and Methods Six dogs were selected and randomly divided into three groups using different doses contrast agent, Iohexol, at 1.62, 2.02, 2.40ml/kg, respectively. Each dosage group was repeated three times with at least 48 hours scan interval. Imaging quality of renal parenchymal, renal artery and visualization of renal artery branches were graded on axial and post-processed views. The CT values of main renal artery and branches as well as signal-to-noise ratio in abdominal aorta were measured. Results There was no statistical difference in renal parenchymal imaging among the three groups (P0.05). Main renal artery and its 3rd-order branches were clearly shown in all three groups without statistical difference in scoring (P 0.05). There was no statistical difference in comparing CT values in different portions in main renal artery and its 3rd-order branches (P 0.05). There was no statistical difference in signal-to-noise ratio within abdominal aorta among all groups (P0.05). Conclusion High quality images can be obtained in imaging dog renal arteries with MSCT using low dose contrast media of 1.62ml/kg.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose To investigate the feasibility of dog renal artery imaging with multi-slice CT (MSCT) using different doses contrast media. Materials and Methods Six dogs were selected and randomly divided into three groups using different doses contrast agent, Iohexol, at 1.62, 2.02, 2.40ml/kg, respectively. Each dosage group was repeated three times with at least 48 hours scan interval. Imaging quality of renal parenchymal, renal artery and visualization of renal artery branches were graded on axial and post-processed views. The CT values of main renal artery and branches as well as signal-to-noise ratio in abdominal aorta were measured. Results There was no statistical difference in renal parenchymal imaging among the three groups (P0.05). Main renal artery and its 3rd-order branches were clearly shown in all three groups without statistical difference in scoring (P 0.05). There was no statistical difference in comparing CT values in different portions in main renal artery and its 3rd-order branches (P 0.05). There was no statistical difference in signal-to-noise ratio within abdominal aorta among all groups (P0.05). Conclusion High quality images can be obtained in imaging dog renal arteries with MSCT using low dose contrast media of 1.62ml/kg.

Key concepts: Medicine, Renal artery, Iohexol, Abdominal aorta, Aorta, Radiology, Contrast (vision), Contrast medium

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Dog Renal Artery Imaging with Multi-slice CT Using Different Doses Contrast Media — Research Paper | ScholarLens