2008Journal of Shenyang Jianzhu UniversityRequires access

Simulation and Analysis of the Radiant Floor Cooling and Displacement Ventilation System

Yufeng Zhang

Open publisher page 1 citations

Abstract

This study aims at developing a radiant floor cooling system using the existing radiant floor heating system.Using CFD(computational fluid dynamics) software,this paper analyzes the airflow distribution under displacement ventilation,the radiant floor cooling and the hybrid system.The temperature field,velocity field and the vertical gradient are analyzed under different loads.The simulation results show that the thermal comfort of hybrid system is the best,and the risk of condensation is lower than the radiant floor cooling operating individually.The internal heat sources influence airflow distribution enormously.We can draw the conclusion that the hybrid system can be used with wide range of cooling load.It can improve the cooling capacity of radiant floor cooling and avoid condensation on the cooling floor surface.

About this research paper

What this paper is about

This study aims at developing a radiant floor cooling system using the existing radiant floor heating system.Using CFD(computational fluid dynamics) software,this paper analyzes the airflow distribution under displacement ventilation,the radiant floor cooling and the hybrid system.The temperature field,velocity field and the vertical gradient are analyzed under different loads.The simulation results show that the thermal comfort of hybrid system is the best,and the risk of condensation is lower than the radiant floor cooling operating individually.The internal heat sources influence airflow distribution enormously.We can draw the conclusion that the hybrid system can be used with wide range of cooling load.It can improve the cooling capacity of radiant floor cooling and avoid condensation on the cooling floor surface.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aims at developing a radiant floor cooling system using the existing radiant floor heating system.Using CFD(computational fluid dynamics) software,this paper analyzes the airflow distribution under displacement ventilation,the radiant floor cooling and the hybrid system.The temperature field,velocity field and the vertical gradient are analyzed under different loads.The simulation results show that the thermal comfort of hybrid system is the best,and the risk of condensation is lower than the radiant floor cooling operating individually.The internal heat sources influence airflow distribution enormously.We can draw the conclusion that the hybrid system can be used with wide range of cooling load.It can improve the cooling capacity of radiant floor cooling and avoid condensation on the cooling floor surface.

Key concepts: Displacement ventilation, Radiant cooling, Airflow, Computational fluid dynamics, Passive cooling, Water cooling, Radiant heating, Thermal comfort