Comparison of Improved GTS1-2 Radiosonde with International Radiosonde Comparison Test Data
Cma Meteorological
Abstract
Cma Meteorological
Abstract
The assessment of domestic scholars and WMO suggests that the GTS1-2radiosonde needs technological improvement to meet the needs of operational upper-air observation,which was conducted on the basis of original technical structure in 2012and the improved radiosonde was temporarily named GTS12A.In August 2012,its test was carried out in the Yangjiang radiosonde station.The results show that it performed well in temperature measurement at night with system error less than-0.3 ℃ and overall standard deviation within 0.2 ℃;but in the daytime,except at upper levels and when in/out of clouds,overall its system error is-0.3 ℃ and its standard deviation is less than 0.4 ℃.As for pressure measurements,in the near-surface layer,the system error is about-1.5hPa,and its accuracy and stability are better than GTS1-2.Especially its standard deviation is less than 0.7hPa within full range.Its humidity has good consistency with RS92with sensitivity better than GTS1-2and overall system error and standard deviation within 10%RH.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The assessment of domestic scholars and WMO suggests that the GTS1-2radiosonde needs technological improvement to meet the needs of operational upper-air observation,which was conducted on the basis of original technical structure in 2012and the improved radiosonde was temporarily named GTS12A.In August 2012,its test was carried out in the Yangjiang radiosonde station.The results show that it performed well in temperature measurement at night with system error less than-0.3 ℃ and overall standard deviation within 0.2 ℃;but in the daytime,except at upper levels and when in/out of clouds,overall its system error is-0.3 ℃ and its standard deviation is less than 0.4 ℃.As for pressure measurements,in the near-surface layer,the system error is about-1.5hPa,and its accuracy and stability are better than GTS1-2.Especially its standard deviation is less than 0.7hPa within full range.Its humidity has good consistency with RS92with sensitivity better than GTS1-2and overall system error and standard deviation within 10%RH.
Key concepts: Radiosonde, Standard deviation, Meteorology, Consistency (knowledge bases), Environmental science, Range (aeronautics), Statistics, Mathematics