2009Coal science and technologyRequires access

Calculation Method of Site Measured Piston Pump Discharged Volume Base on Inhaled Volume Efficiency

Miao Wu

Open publisher page 0 citations

Abstract

In order to accurate measure the actual discharging volume of the piston pump,according to the discharging volume calculation principle of the reciprocating piston pump,the actual discharging volume of the piston pump was calculated base on the measurement method of the inhaled volume efficiency.First according to the main factors affected to the inhaled volume efficiency,an inhaled volume efficiency measurement and test device of high density sticky material was developed.With the modification on the quality fraction,inhaled velocity,material bunk pressure,material cylinder length and diameter ratio and other performance of the material,the inhaled volume efficiency of the piston pump could be studied by the device.The paper introduced the test and measurement principle of the measurement and test device.Also the paper in detail stated the composition of the device,including the test procedure to measure the inhaled volume efficiency.In the final,a mathematical model to calculate the actual discharging was set up base on the inhaled volume efficiency.With the method to calculate the actual discharging of the piston pump,the actual discharging would be not only more closed to the project reality,but could be applied to study the actual discharging under any performances closed to the theoretical discharging,which could provide the technical basis to improve the pumping efficiency and project application.

About this research paper

What this paper is about

In order to accurate measure the actual discharging volume of the piston pump,according to the discharging volume calculation principle of the reciprocating piston pump,the actual discharging volume of the piston pump was calculated base on the measurement method of the inhaled volume efficiency.First according to the main factors affected to the inhaled volume efficiency,an inhaled volume efficiency measurement and test device of high density sticky material was developed.With the modification on the quality fraction,inhaled velocity,material bunk pressure,material cylinder length and diameter ratio and other performance of the material,the inhaled volume efficiency of the piston pump could be studied by the device.The paper introduced the test and measurement principle of the measurement and test device.Also the paper in detail stated the composition of the device,including the test procedure to measure the inhaled volume efficiency.In the final,a mathematical model to calculate the actual discharging was set up base on the inhaled volume efficiency.With the method to calculate the actual discharging of the piston pump,the actual discharging would be not only more closed to the project reality,but could be applied to study the actual discharging under any performances closed to the theoretical discharging,which could provide the technical basis to improve the pumping efficiency and project application.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to accurate measure the actual discharging volume of the piston pump,according to the discharging volume calculation principle of the reciprocating piston pump,the actual discharging volume of the piston pump was calculated base on the measurement method of the inhaled volume efficiency.First according to the main factors affected to the inhaled volume efficiency,an inhaled volume efficiency measurement and test device of high density sticky material was developed.With the modification on the quality fraction,inhaled velocity,material bunk pressure,material cylinder length and diameter ratio and other performance of the material,the inhaled volume efficiency of the piston pump could be studied by the device.The paper introduced the test and measurement principle of the measurement and test device.Also the paper in detail stated the composition of the device,including the test procedure to measure the inhaled volume efficiency.In the final,a mathematical model to calculate the actual discharging was set up base on the inhaled volume efficiency.With the method to calculate the actual discharging of the piston pump,the actual discharging would be not only more closed to the project reality,but could be applied to study the actual discharging under any performances closed to the theoretical discharging,which could provide the technical basis to improve the pumping efficiency and project application.

Key concepts: Piston (optics), Piston pump, Volume (thermodynamics), Volumetric efficiency, Base (topology), Reciprocating pump, Reciprocating motion, Measure (data warehouse)

Related papers

Back to paper searchBrowse research topicsOriginal source
Calculation Method of Site Measured Piston Pump Discharged Volume Base on Inhaled Volume Efficiency — Research Paper | ScholarLens