Pretreatment of Coking Wastewater in Circulating Micro-electrolysis Process with Aeration
Chen Li-li
Abstract
Chen Li-li
Abstract
The circulating micro-electrolysis process with aeration was employed for pretreatment of coking wastewater.The experiment results showed that color removal and COD removal were 100% and 77.6%,respectively,when aeration flow was 5 m3/h,circulating time was 4 h,pH value was 3,and wastewater flow was 1 L/min.And the B/C in coking wastewater increased from 0.18 to 0.38.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The circulating micro-electrolysis process with aeration was employed for pretreatment of coking wastewater.The experiment results showed that color removal and COD removal were 100% and 77.6%,respectively,when aeration flow was 5 m3/h,circulating time was 4 h,pH value was 3,and wastewater flow was 1 L/min.And the B/C in coking wastewater increased from 0.18 to 0.38.
Key concepts: Aeration, Wastewater, Electrolysis, Pulp and paper industry, Chemistry, Activated sludge, Waste management, Environmental science