2012•Chinese Journal of Analysis LaboratoryRequires access

Determination of trace Cd(II) and Zn(II) on a micro-column filled with polyacrylonitrile coupled with flame atomic absorption spectrometry

Peng Yang

Open publisher page 0 citations

Abstract

In this paper,the adsorption properties of Cd2+ and Zn2+ on the micro-column(2.5cm×4 mm i.d) filled with polyacrylonitrile microsphere as the adsorption material synthesized by ourselves were studied by flame atomic absorption spectrometry.The Adsorption conditions f Cd2+ and Zn2+ on the column such as pH,flow rate and time et al were optimized.The results showed that at the room temperature,pH of solution was 5~6,the flow rate and time of loading sample were 6 mL/min,and 10 min and the eluant 3.0 mL/min and 1 min respectively.The as-prepared micro-column had excellent adsorption properties and high adsorption capacities for Cd2+ and Zn2+ which reached 47.6 and 39.3 mg/g respectively.0.50 mol/L chloride acid showed the best desorption property and the recovery reached 99%.The detection limits(3σ,n=10) were 1.06 and 0.855 μg/L with the relative standard deviations(RSDs) of 2.6 and 1.8% respectively.This method was applied to the determination of trace cadmium and zinc from environmental samples,the recoveries were in the range of 94.0%~102.6% and 94.6%~100.4% respectively.

About this research paper

What this paper is about

In this paper,the adsorption properties of Cd2+ and Zn2+ on the micro-column(2.5cm×4 mm i.d) filled with polyacrylonitrile microsphere as the adsorption material synthesized by ourselves were studied by flame atomic absorption spectrometry.The Adsorption conditions f Cd2+ and Zn2+ on the column such as pH,flow rate and time et al were optimized.The results showed that at the room temperature,pH of solution was 5~6,the flow rate and time of loading sample were 6 mL/min,and 10 min and the eluant 3.0 mL/min and 1 min respectively.The as-prepared micro-column had excellent adsorption properties and high adsorption capacities for Cd2+ and Zn2+ which reached 47.6 and 39.3 mg/g respectively.0.50 mol/L chloride acid showed the best desorption property and the recovery reached 99%.The detection limits(3σ,n=10) were 1.06 and 0.855 μg/L with the relative standard deviations(RSDs) of 2.6 and 1.8% respectively.This method was applied to the determination of trace cadmium and zinc from environmental samples,the recoveries were in the range of 94.0%~102.6% and 94.6%~100.4% respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper,the adsorption properties of Cd2+ and Zn2+ on the micro-column(2.5cm×4 mm i.d) filled with polyacrylonitrile microsphere as the adsorption material synthesized by ourselves were studied by flame atomic absorption spectrometry.The Adsorption conditions f Cd2+ and Zn2+ on the column such as pH,flow rate and time et al were optimized.The results showed that at the room temperature,pH of solution was 5~6,the flow rate and time of loading sample were 6 mL/min,and 10 min and the eluant 3.0 mL/min and 1 min respectively.The as-prepared micro-column had excellent adsorption properties and high adsorption capacities for Cd2+ and Zn2+ which reached 47.6 and 39.3 mg/g respectively.0.50 mol/L chloride acid showed the best desorption property and the recovery reached 99%.The detection limits(3σ,n=10) were 1.06 and 0.855 μg/L with the relative standard deviations(RSDs) of 2.6 and 1.8% respectively.This method was applied to the determination of trace cadmium and zinc from environmental samples,the recoveries were in the range of 94.0%~102.6% and 94.6%~100.4% respectively.

Key concepts: Polyacrylonitrile, Chemistry, Adsorption, Desorption, Zinc, Cadmium, Detection limit, Atomic absorption spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace Cd(II) and Zn(II) on a micro-column filled with polyacrylonitrile coupled with flame atomic absorption spectrometry — Research Paper | ScholarLens