2011•Physical Testing and Chemical AnalysisRequires access

GC-MS Determination of Residual Amounts of 19 Pesticides in Drinking Water with Enrichment by Liquid-Liquid Extraction

Huamei Yang

Open publisher page 0 citations

Abstract

GC-MS with enrichment by liquid-liquid extraction was applied to the determination of residual amounts of 19 pesticides in drinking water.The pesticides in sample were extracted thrice with dichloromethane (20,10,10 mL),the extracts were combined and evaporated rotationally to 1.0 mL,from which 1.0μL was taken for GC-MS analysis.The HP-5MS capillary column was used for separation,and EI source with SIM mode was used in MS determination.Phenanthrene-d_(10) was added as internal standard,and values of peak area were used in quantification.Linearities for the 19 pesticides were obtained in definite concentration ranges,with values of detection limits(3S/N) ranged from 0.002 to 0.10 mg·L~(-1).Values of recovery found by standard addition method were in the range of 81.1%-103.0%with RSD's(n=6) ranged from 0.25%to 7.7%.

About this research paper

What this paper is about

GC-MS with enrichment by liquid-liquid extraction was applied to the determination of residual amounts of 19 pesticides in drinking water.The pesticides in sample were extracted thrice with dichloromethane (20,10,10 mL),the extracts were combined and evaporated rotationally to 1.0 mL,from which 1.0μL was taken for GC-MS analysis.The HP-5MS capillary column was used for separation,and EI source with SIM mode was used in MS determination.Phenanthrene-d_(10) was added as internal standard,and values of peak area were used in quantification.Linearities for the 19 pesticides were obtained in definite concentration ranges,with values of detection limits(3S/N) ranged from 0.002 to 0.10 mg·L~(-1).Values of recovery found by standard addition method were in the range of 81.1%-103.0%with RSD's(n=6) ranged from 0.25%to 7.7%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

GC-MS with enrichment by liquid-liquid extraction was applied to the determination of residual amounts of 19 pesticides in drinking water.The pesticides in sample were extracted thrice with dichloromethane (20,10,10 mL),the extracts were combined and evaporated rotationally to 1.0 mL,from which 1.0μL was taken for GC-MS analysis.The HP-5MS capillary column was used for separation,and EI source with SIM mode was used in MS determination.Phenanthrene-d_(10) was added as internal standard,and values of peak area were used in quantification.Linearities for the 19 pesticides were obtained in definite concentration ranges,with values of detection limits(3S/N) ranged from 0.002 to 0.10 mg·L~(-1).Values of recovery found by standard addition method were in the range of 81.1%-103.0%with RSD's(n=6) ranged from 0.25%to 7.7%.

Key concepts: Chromatography, Dichloromethane, Chemistry, Extraction (chemistry), Pesticide, Internal standard, Detection limit, Sample preparation

Related papers

Back to paper searchBrowse research topicsOriginal source
GC-MS Determination of Residual Amounts of 19 Pesticides in Drinking Water with Enrichment by Liquid-Liquid Extraction — Research Paper | ScholarLens