A 4πβ+4πγ equipment for radioactivity measurement

Xiaobing He

Open publisher page 2 citations

Abstract

Abstrcat A 4πβ+4πγ equipment for radioactivity measurement is made up of a 4π flow-gas proportional counter, a well-type NaI(Tl) detector and a HPGe detector. We place the 4πβ counter onto the HPGe detector and into the well of NaI(Tl) detector for carrying out the measurement of β-ray detection efficiency, radioactivity and γ-ray emission probability all the time. The radioactivity of ()~(60)Co, ()~(134)Cs and (()~(166m)Ho) were determined by 4πβ+4πγ method for radioactivity measurement, the result was 127.64(1±0.34%)Bq/mg for ()~(60)Co,191.68(1±0.27%) Bq/mg for ()~(134)Cs and 130.17(1±0.21%)Bq/mg for ()~(166m)Ho , which were well agreed with the results of native or national compared measurement. And the mainγ-ray emission probability of ()~(134)Cs and ()~(166m)Ho were also detemined and the results were accorded with the literature in uncertainty.

About this research paper

What this paper is about

Abstrcat A 4πβ+4πγ equipment for radioactivity measurement is made up of a 4π flow-gas proportional counter, a well-type NaI(Tl) detector and a HPGe detector. We place the 4πβ counter onto the HPGe detector and into the well of NaI(Tl) detector for carrying out the measurement of β-ray detection efficiency, radioactivity and γ-ray emission probability all the time. The radioactivity of ()~(60)Co, ()~(134)Cs and (()~(166m)Ho) were determined by 4πβ+4πγ method for radioactivity measurement, the result was 127.64(1±0.34%)Bq/mg for ()~(60)Co,191.68(1±0.27%) Bq/mg for ()~(134)Cs and 130.17(1±0.21%)Bq/mg for ()~(166m)Ho , which were well agreed with the results of native or national compared measurement. And the mainγ-ray emission probability of ()~(134)Cs and ()~(166m)Ho were also detemined and the results were accorded with the literature in uncertainty.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstrcat A 4πβ+4πγ equipment for radioactivity measurement is made up of a 4π flow-gas proportional counter, a well-type NaI(Tl) detector and a HPGe detector. We place the 4πβ counter onto the HPGe detector and into the well of NaI(Tl) detector for carrying out the measurement of β-ray detection efficiency, radioactivity and γ-ray emission probability all the time. The radioactivity of ()~(60)Co, ()~(134)Cs and (()~(166m)Ho) were determined by 4πβ+4πγ method for radioactivity measurement, the result was 127.64(1±0.34%)Bq/mg for ()~(60)Co,191.68(1±0.27%) Bq/mg for ()~(134)Cs and 130.17(1±0.21%)Bq/mg for ()~(166m)Ho , which were well agreed with the results of native or national compared measurement. And the mainγ-ray emission probability of ()~(134)Cs and ()~(166m)Ho were also detemined and the results were accorded with the literature in uncertainty.