Development of a time-resolved fluoroimmunoassay kit for detecting C-peptide
Zheng Guixing
Abstract
Zheng Guixing
Abstract
Objective To develop a time-resolved fluoroimmunoassay(TRFIA) kit for detection of C-peptide in serum.Methods Two anti-C-peptide monoclonal antibodies were used to develop the sandwich TRFIA kit for detection of C-peptide in serum and its methodology was evaluated.Results The detection range of C-peptide was 0.4-20 ng/mL.The analytical sensitivity was 0.23 ng/mL.The intra-assay and inter-assay coefficients of variation were 7.99% and 11.97% respectively.The recovery rate was 99.57%.There was no cross-reactivity with insulin and proinsulin.The TRFIA C-peptide reagents could be stored at 4 ℃ for 9 months and at 37 ℃ for 7 days.The reference value for TRFIA C-peptide kit in healthy subjects(200 cases) was 0.358-3.590 ng/mL.The correlation coefficient of blood samples detection results(122 cases) between this TRFIA kit and commercially available electrochemiluminescense immunoassay C-peptide kits was 0.943 2.The linear equation was Y=0.985 4X+0.506 3.Conclusions The developed TRFIA C-peptide kit is valuable for clinical application with good sensitivity,precision,accuracy,specificity and stability.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To develop a time-resolved fluoroimmunoassay(TRFIA) kit for detection of C-peptide in serum.Methods Two anti-C-peptide monoclonal antibodies were used to develop the sandwich TRFIA kit for detection of C-peptide in serum and its methodology was evaluated.Results The detection range of C-peptide was 0.4-20 ng/mL.The analytical sensitivity was 0.23 ng/mL.The intra-assay and inter-assay coefficients of variation were 7.99% and 11.97% respectively.The recovery rate was 99.57%.There was no cross-reactivity with insulin and proinsulin.The TRFIA C-peptide reagents could be stored at 4 ℃ for 9 months and at 37 ℃ for 7 days.The reference value for TRFIA C-peptide kit in healthy subjects(200 cases) was 0.358-3.590 ng/mL.The correlation coefficient of blood samples detection results(122 cases) between this TRFIA kit and commercially available electrochemiluminescense immunoassay C-peptide kits was 0.943 2.The linear equation was Y=0.985 4X+0.506 3.Conclusions The developed TRFIA C-peptide kit is valuable for clinical application with good sensitivity,precision,accuracy,specificity and stability.
Key concepts: Proinsulin, Peptide, Immunoassay, Chromatography, C-peptide, Chemistry, Coefficient of variation, Medicine