Many factors attribute to the capacity of wind power integration into grid,among which the most important one is the peak load regulation of the power system.Meanwhile,the peak load regulation has been greatly influenced by the scale,structure of the power system,load impedance,peak performance of the thermal power units,etc.According to the technical problems such as reactive power balance of regional power network,voltage stability,power transmission passage capacity,this paper,based on the design of grid-connected system and the relating fields,proposes responding technical measures.Then from the capacity of peak load regulation of Anhui Power Grid,the paper analyses the integration capacity of Laian Wind Power into Anhui Power Grid.

About this research paper

What this paper is about

Many factors attribute to the capacity of wind power integration into grid,among which the most important one is the peak load regulation of the power system.Meanwhile,the peak load regulation has been greatly influenced by the scale,structure of the power system,load impedance,peak performance of the thermal power units,etc.According to the technical problems such as reactive power balance of regional power network,voltage stability,power transmission passage capacity,this paper,based on the design of grid-connected system and the relating fields,proposes responding technical measures.Then from the capacity of peak load regulation of Anhui Power Grid,the paper analyses the integration capacity of Laian Wind Power into Anhui Power Grid.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Many factors attribute to the capacity of wind power integration into grid,among which the most important one is the peak load regulation of the power system.Meanwhile,the peak load regulation has been greatly influenced by the scale,structure of the power system,load impedance,peak performance of the thermal power units,etc.According to the technical problems such as reactive power balance of regional power network,voltage stability,power transmission passage capacity,this paper,based on the design of grid-connected system and the relating fields,proposes responding technical measures.Then from the capacity of peak load regulation of Anhui Power Grid,the paper analyses the integration capacity of Laian Wind Power into Anhui Power Grid.