2011•Rock and Mineral AnalysisRequires access

The Comparison of Three Sample Pretreatment Methods in Determination of Gallium in Bauxite Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry

Yang Zai-ming

Open publisher page 0 citations

Abstract

The bauxite ores were digested by three different pretreatments as HCl-HNO3-HF-HClO4 mixed acids,HF-HNO3-H2SO4 mixed acids and alkali fusion.The Ga was measured by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES).The HCl-HNO3-HF-HClO4 mixed acids incompletely dissolved the bauxite ores with a large amount of residues.Due to the Ga reacts with HCl to form GaCl3 which is easy to volatilize from the solution system,the measured Ga concentration is much lower than the certified value.The bauxite ores also were incompletely dissolved by HF-HNO3-H2SO4 mixed acids with lower concentration for Ga.Nevertheless,the bauxite ores were completely digested by alkali fusion with clear solution.The NaCl in solution can protect Ga lossing by volatilization to obtain accurate result.The method of alkali fusion,HCl extraction and measurement by ICP-AES produces high precision and accurate result for Ga with detection limit of 3.21 μg/g and less than 5% RSD(n=11).The obtained result is generally consistent with certified value of both first and second grade national standard reference materials.

About this research paper

What this paper is about

The bauxite ores were digested by three different pretreatments as HCl-HNO3-HF-HClO4 mixed acids,HF-HNO3-H2SO4 mixed acids and alkali fusion.The Ga was measured by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES).The HCl-HNO3-HF-HClO4 mixed acids incompletely dissolved the bauxite ores with a large amount of residues.Due to the Ga reacts with HCl to form GaCl3 which is easy to volatilize from the solution system,the measured Ga concentration is much lower than the certified value.The bauxite ores also were incompletely dissolved by HF-HNO3-H2SO4 mixed acids with lower concentration for Ga.Nevertheless,the bauxite ores were completely digested by alkali fusion with clear solution.The NaCl in solution can protect Ga lossing by volatilization to obtain accurate result.The method of alkali fusion,HCl extraction and measurement by ICP-AES produces high precision and accurate result for Ga with detection limit of 3.21 μg/g and less than 5% RSD(n=11).The obtained result is generally consistent with certified value of both first and second grade national standard reference materials.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The bauxite ores were digested by three different pretreatments as HCl-HNO3-HF-HClO4 mixed acids,HF-HNO3-H2SO4 mixed acids and alkali fusion.The Ga was measured by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES).The HCl-HNO3-HF-HClO4 mixed acids incompletely dissolved the bauxite ores with a large amount of residues.Due to the Ga reacts with HCl to form GaCl3 which is easy to volatilize from the solution system,the measured Ga concentration is much lower than the certified value.The bauxite ores also were incompletely dissolved by HF-HNO3-H2SO4 mixed acids with lower concentration for Ga.Nevertheless,the bauxite ores were completely digested by alkali fusion with clear solution.The NaCl in solution can protect Ga lossing by volatilization to obtain accurate result.The method of alkali fusion,HCl extraction and measurement by ICP-AES produces high precision and accurate result for Ga with detection limit of 3.21 μg/g and less than 5% RSD(n=11).The obtained result is generally consistent with certified value of both first and second grade national standard reference materials.

Key concepts: Bauxite, Chemistry, Inductively coupled plasma, Alkali metal, Gallium, Detection limit, Atomic emission spectroscopy, Inductively coupled plasma atomic emission spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
The Comparison of Three Sample Pretreatment Methods in Determination of Gallium in Bauxite Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry — Research Paper | ScholarLens