The Comparison of Three Sample Pretreatment Methods in Determination of Gallium in Bauxite Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry
Yang Zai-ming
Abstract
Yang Zai-ming
Abstract
The bauxite ores were digested by three different pretreatments as HCl-HNO3-HF-HClO4 mixed acids,HF-HNO3-H2SO4 mixed acids and alkali fusion.The Ga was measured by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES).The HCl-HNO3-HF-HClO4 mixed acids incompletely dissolved the bauxite ores with a large amount of residues.Due to the Ga reacts with HCl to form GaCl3 which is easy to volatilize from the solution system,the measured Ga concentration is much lower than the certified value.The bauxite ores also were incompletely dissolved by HF-HNO3-H2SO4 mixed acids with lower concentration for Ga.Nevertheless,the bauxite ores were completely digested by alkali fusion with clear solution.The NaCl in solution can protect Ga lossing by volatilization to obtain accurate result.The method of alkali fusion,HCl extraction and measurement by ICP-AES produces high precision and accurate result for Ga with detection limit of 3.21 μg/g and less than 5% RSD(n=11).The obtained result is generally consistent with certified value of both first and second grade national standard reference materials.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The bauxite ores were digested by three different pretreatments as HCl-HNO3-HF-HClO4 mixed acids,HF-HNO3-H2SO4 mixed acids and alkali fusion.The Ga was measured by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES).The HCl-HNO3-HF-HClO4 mixed acids incompletely dissolved the bauxite ores with a large amount of residues.Due to the Ga reacts with HCl to form GaCl3 which is easy to volatilize from the solution system,the measured Ga concentration is much lower than the certified value.The bauxite ores also were incompletely dissolved by HF-HNO3-H2SO4 mixed acids with lower concentration for Ga.Nevertheless,the bauxite ores were completely digested by alkali fusion with clear solution.The NaCl in solution can protect Ga lossing by volatilization to obtain accurate result.The method of alkali fusion,HCl extraction and measurement by ICP-AES produces high precision and accurate result for Ga with detection limit of 3.21 μg/g and less than 5% RSD(n=11).The obtained result is generally consistent with certified value of both first and second grade national standard reference materials.
Key concepts: Bauxite, Chemistry, Inductively coupled plasma, Alkali metal, Gallium, Detection limit, Atomic emission spectroscopy, Inductively coupled plasma atomic emission spectroscopy