2014Radiologic PracticeRequires access

Application of 320 row CT in the diagnosis of esophageal atresia combined with tracheoesophageal fistula in neonates

Pan Chun-ya

Open publisher page 0 citations

Abstract

Objective:To explore the value of 320row CT and the post-processing images in the diagnosis of esophageal atresia combind with tracheal-esophageal fistula(CEA-TEF).Methods:Nine suspectd cases of CEA-TEF underwent 320row CT scanning.Post-processing methods included MPR,CPR,MinIP,VR and VE.An experienced technician and a diagnosis physician were responsible for analyzing the images,and according to the need of the diagnosis,making the image post-processing and related measurements.Results:In the 9children,there was CEA-TEF TypeⅢin 8cases and TypeⅠin one case.There was cardiovascular malformations in one of them and imperforate anus in another.Conclusion:320row CT imaging and post processing images can be accurate and non-invasive methods for the diagnosis of CEA-TEF,as well as its classification,fistula location,evaluation of the lung,and whether with other abnormalities.

About this research paper

What this paper is about

Objective:To explore the value of 320row CT and the post-processing images in the diagnosis of esophageal atresia combind with tracheal-esophageal fistula(CEA-TEF).Methods:Nine suspectd cases of CEA-TEF underwent 320row CT scanning.Post-processing methods included MPR,CPR,MinIP,VR and VE.An experienced technician and a diagnosis physician were responsible for analyzing the images,and according to the need of the diagnosis,making the image post-processing and related measurements.Results:In the 9children,there was CEA-TEF TypeⅢin 8cases and TypeⅠin one case.There was cardiovascular malformations in one of them and imperforate anus in another.Conclusion:320row CT imaging and post processing images can be accurate and non-invasive methods for the diagnosis of CEA-TEF,as well as its classification,fistula location,evaluation of the lung,and whether with other abnormalities.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To explore the value of 320row CT and the post-processing images in the diagnosis of esophageal atresia combind with tracheal-esophageal fistula(CEA-TEF).Methods:Nine suspectd cases of CEA-TEF underwent 320row CT scanning.Post-processing methods included MPR,CPR,MinIP,VR and VE.An experienced technician and a diagnosis physician were responsible for analyzing the images,and according to the need of the diagnosis,making the image post-processing and related measurements.Results:In the 9children,there was CEA-TEF TypeⅢin 8cases and TypeⅠin one case.There was cardiovascular malformations in one of them and imperforate anus in another.Conclusion:320row CT imaging and post processing images can be accurate and non-invasive methods for the diagnosis of CEA-TEF,as well as its classification,fistula location,evaluation of the lung,and whether with other abnormalities.

Key concepts: Medicine, Tracheoesophageal fistula, Imperforate anus, Atresia, Radiology, Fistula, Esophagus, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of 320 row CT in the diagnosis of esophageal atresia combined with tracheoesophageal fistula in neonates — Research Paper | ScholarLens