Rapid Determination of Telmisartan in Human Plasma and Study of Bioequivalence of Its Tablets in Healthy Subjects
Wenming Tan
Abstract
Wenming Tan
Abstract
Objective: To develop a HPLC-ESI-MS assay for rapidly determinating telmisartan in human plasma and to evaluate the pharmacokinetics and bioequivalence of two telmisartan tablets in human. Methods: After being deproteined by acetonitril, plasma samples were separated by HPLC-ESI-MS on a reversed-phase C 18 column with a mobile phase of 10 mmol/L ammonium acetate buffer solution (pH 3.5)-methanol (9∶91,V/V) and a fragmentor voltage of 120 V, in which the target ions (m/z) were at 515.5 for telmisartan and 423.4 for the internal standard. The randomized crossover trial was performed in 20 healthy volunteers using the test tablets and reference tablets individually at a single 40 mg dose. Then blood samplings from the subjects were conducted for HPLC-ESI-MS analysis and the main pharmacokinetic parameters were determined thereby. Results: Calibration curve obtained was linear over the range of 0.3012~602.4 μg/L. Determination of a blood sample by this method was completed within 3.5 min. t 1/2, T max and C max were (24.7±4.2) h, (1.8±0.5) h and (219.2±119.0) μg/L for the reference tablets and (23.3±5.6) h, (1.7±0.7) h and (209.8±125.9) μg/L for the test tablets, individually. The relative bioavalability of the test tablets was (100.5±8.3)%. The results of variance analysis and two one-sided t-test showed that there was no significant difference between the two preparations in the AUC and C max. Conclusion: The assay was proved to be rapid, sensitive, accurate and convenient. The two preparations were bioequivalent.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To develop a HPLC-ESI-MS assay for rapidly determinating telmisartan in human plasma and to evaluate the pharmacokinetics and bioequivalence of two telmisartan tablets in human. Methods: After being deproteined by acetonitril, plasma samples were separated by HPLC-ESI-MS on a reversed-phase C 18 column with a mobile phase of 10 mmol/L ammonium acetate buffer solution (pH 3.5)-methanol (9∶91,V/V) and a fragmentor voltage of 120 V, in which the target ions (m/z) were at 515.5 for telmisartan and 423.4 for the internal standard. The randomized crossover trial was performed in 20 healthy volunteers using the test tablets and reference tablets individually at a single 40 mg dose. Then blood samplings from the subjects were conducted for HPLC-ESI-MS analysis and the main pharmacokinetic parameters were determined thereby. Results: Calibration curve obtained was linear over the range of 0.3012~602.4 μg/L. Determination of a blood sample by this method was completed within 3.5 min. t 1/2, T max and C max were (24.7±4.2) h, (1.8±0.5) h and (219.2±119.0) μg/L for the reference tablets and (23.3±5.6) h, (1.7±0.7) h and (209.8±125.9) μg/L for the test tablets, individually. The relative bioavalability of the test tablets was (100.5±8.3)%. The results of variance analysis and two one-sided t-test showed that there was no significant difference between the two preparations in the AUC and C max. Conclusion: The assay was proved to be rapid, sensitive, accurate and convenient. The two preparations were bioequivalent.
Key concepts: Bioequivalence, Telmisartan, Chromatography, Pharmacokinetics, High-performance liquid chromatography, Chemistry, Ammonium acetate, Human plasma