2012Zhongguo yixue yingxiang jishuRequires access

Application of low-dose chest CT screening with iterative reconstruction technique(iDose~4)

Jianghong Chen

Open publisher page 0 citations

Abstract

Objective To assess the program of low dose chest CT screening with iterative reconstruction technique(iDose4).Methods Totally 120 subjects who underwent chest CT screening were divided into 3 groups according to body mass index(BMI): Group A(BMI≤22),group B(22BMI26) and group C(BMI≥26).Z-axial dose modulation(Z-DOM) technique was used to preset tube current of group A,group B and group C as 35 mAs,45 mAs and 60 mAs,respectively.Then the images were reconstructed with standard filtered back projection(FBP),iDose3,iDose5 and iDose7,respectively.CT dose index volumes(CTDIvol) and dose length product(DLP) were recorded,while effective dose(ED) was estimated.The imaging quality was assessed by 2 radiologists.Results The images of each group were acceptable.The average CTDIvol for group A,B and C was(0.69±0.08)mGy,(1.09±0.17)mGy and(1.95±0.43)mGy,respectively,and the average ED was(0.33±0.05)mSv,(0.50±0.11) mSv and(0.87±0.23) mSv,respectively.Conclusion Application of iDose4 iterative reconstruction technique based on BMI can achieve satisfactory scanning program of chest low-dose screening.

About this research paper

What this paper is about

Objective To assess the program of low dose chest CT screening with iterative reconstruction technique(iDose4).Methods Totally 120 subjects who underwent chest CT screening were divided into 3 groups according to body mass index(BMI): Group A(BMI≤22),group B(22BMI26) and group C(BMI≥26).Z-axial dose modulation(Z-DOM) technique was used to preset tube current of group A,group B and group C as 35 mAs,45 mAs and 60 mAs,respectively.Then the images were reconstructed with standard filtered back projection(FBP),iDose3,iDose5 and iDose7,respectively.CT dose index volumes(CTDIvol) and dose length product(DLP) were recorded,while effective dose(ED) was estimated.The imaging quality was assessed by 2 radiologists.Results The images of each group were acceptable.The average CTDIvol for group A,B and C was(0.69±0.08)mGy,(1.09±0.17)mGy and(1.95±0.43)mGy,respectively,and the average ED was(0.33±0.05)mSv,(0.50±0.11) mSv and(0.87±0.23) mSv,respectively.Conclusion Application of iDose4 iterative reconstruction technique based on BMI can achieve satisfactory scanning program of chest low-dose screening.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the program of low dose chest CT screening with iterative reconstruction technique(iDose4).Methods Totally 120 subjects who underwent chest CT screening were divided into 3 groups according to body mass index(BMI): Group A(BMI≤22),group B(22BMI26) and group C(BMI≥26).Z-axial dose modulation(Z-DOM) technique was used to preset tube current of group A,group B and group C as 35 mAs,45 mAs and 60 mAs,respectively.Then the images were reconstructed with standard filtered back projection(FBP),iDose3,iDose5 and iDose7,respectively.CT dose index volumes(CTDIvol) and dose length product(DLP) were recorded,while effective dose(ED) was estimated.The imaging quality was assessed by 2 radiologists.Results The images of each group were acceptable.The average CTDIvol for group A,B and C was(0.69±0.08)mGy,(1.09±0.17)mGy and(1.95±0.43)mGy,respectively,and the average ED was(0.33±0.05)mSv,(0.50±0.11) mSv and(0.87±0.23) mSv,respectively.Conclusion Application of iDose4 iterative reconstruction technique based on BMI can achieve satisfactory scanning program of chest low-dose screening.

Key concepts: Medicine, Effective dose (radiation), Nuclear medicine, Body mass index, Iterative reconstruction, Computed tomography, Tomography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of low-dose chest CT screening with iterative reconstruction technique(iDose~4) — Research Paper | ScholarLens