Based on the measurement principle of thin-plate weir flow,a new type of channel measurement device with adjustable stage-discharge was designed.Through the experiments,the free discharge theoretical calculation formulae of the flow measurement device were fitted under six different angles of elevation,and the relational curves of the flow and the weir head were drawn.The results showed that there was a good correlation between the flow and the weir head with maximum relative error 3.83%.At the same flow,the smaller the angle of elevation,the larger the weir head.The critical submergence degree of the device was more than 0.90.Equipped with water level control and flow measurement function,the device could be applied to replace channel intake gate and check gate.

About this research paper

What this paper is about

Based on the measurement principle of thin-plate weir flow,a new type of channel measurement device with adjustable stage-discharge was designed.Through the experiments,the free discharge theoretical calculation formulae of the flow measurement device were fitted under six different angles of elevation,and the relational curves of the flow and the weir head were drawn.The results showed that there was a good correlation between the flow and the weir head with maximum relative error 3.83%.At the same flow,the smaller the angle of elevation,the larger the weir head.The critical submergence degree of the device was more than 0.90.Equipped with water level control and flow measurement function,the device could be applied to replace channel intake gate and check gate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the measurement principle of thin-plate weir flow,a new type of channel measurement device with adjustable stage-discharge was designed.Through the experiments,the free discharge theoretical calculation formulae of the flow measurement device were fitted under six different angles of elevation,and the relational curves of the flow and the weir head were drawn.The results showed that there was a good correlation between the flow and the weir head with maximum relative error 3.83%.At the same flow,the smaller the angle of elevation,the larger the weir head.The critical submergence degree of the device was more than 0.90.Equipped with water level control and flow measurement function,the device could be applied to replace channel intake gate and check gate.

Key concepts: Weir, Flow measurement, Head (geology), Flow (mathematics), Discharge coefficient, Flow coefficient, Open-channel flow, Channel (broadcasting)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Flow Controlled Channel Measurement Device — Research Paper | ScholarLens