Determination of flavonoids in onion by HPLC-DAD
Ren Qian
Abstract
Ren Qian
Abstract
Objective To establish a high performance liquid chromatography coupled with a diode array detector(HPLC-DAD)method for the determination of major flavonoids in onion.Methods The chromatographic separation was performed in a SHIMADZU VP-ODS(250mm×4.6mm,5μm)column.The mobile phase was composed of water(A)and acetonitrile(B)using gradient elution.The column temperature was 30℃ with the flow rate 1.0ml/min,and UV absorbance was detected at a wavelength of 350 nm.Firstly,the flavonoids were identified by maximum UV absorption wavelength.Then,the rutin was used as a standard substance to establish the standard curve to determine the major flavonoids in onion.Results The HPLC-DAD method was established and validated to determine the major flavonoids.The calibration curve was linear in the range of 5.0~502.5μg/ml with good linearity(r=0.9995),repeatability(RSD4.1%),intra-day and inter-day precision(RSD3.3%),recovery(95.1% ~103.2%),limit of detection(0.3μg/ml),and limit of quantification(1.0μg/ml).The content of flavonoids in onion was 2.8 mg/g.Conclusion The method is convenient,feasible,and accurate for the determination of major flavonoids in onion.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a high performance liquid chromatography coupled with a diode array detector(HPLC-DAD)method for the determination of major flavonoids in onion.Methods The chromatographic separation was performed in a SHIMADZU VP-ODS(250mm×4.6mm,5μm)column.The mobile phase was composed of water(A)and acetonitrile(B)using gradient elution.The column temperature was 30℃ with the flow rate 1.0ml/min,and UV absorbance was detected at a wavelength of 350 nm.Firstly,the flavonoids were identified by maximum UV absorption wavelength.Then,the rutin was used as a standard substance to establish the standard curve to determine the major flavonoids in onion.Results The HPLC-DAD method was established and validated to determine the major flavonoids.The calibration curve was linear in the range of 5.0~502.5μg/ml with good linearity(r=0.9995),repeatability(RSD4.1%),intra-day and inter-day precision(RSD3.3%),recovery(95.1% ~103.2%),limit of detection(0.3μg/ml),and limit of quantification(1.0μg/ml).The content of flavonoids in onion was 2.8 mg/g.Conclusion The method is convenient,feasible,and accurate for the determination of major flavonoids in onion.
Key concepts: Chromatography, Repeatability, Calibration curve, Rutin, High-performance liquid chromatography, Absorbance, Chemistry, Detection limit