2010Anhui nongye kexueRequires access

Reaction System Optimization for the Detection of Salmonella by Loop-mediated Isothermal Amplification Technology

Shengkai Zhang

Open publisher page 0 citations

Abstract

[Objective] The research aimed to establish loop-mediated isothermal amplification (LAMP) technology for rapid detection of Salmonella.[Method] The primers were designed according to the Salmonella-specific gene (invA) sequence as the target sequence.And the sequence was amplified under the isothermal conditions.The reaction conditions were optimized including Mg2+ concentration,reaction temperature and time etc.And Salmonella stains were detected and identified.[Result] The results indicated that the best amplification conditions was 62 ℃ for 40 min when Mg2+ concentration was 2.0 mmol/L.The sensitivity of LAMP detection of Salmonella stains was 7.8 cfu/ml.[Conclusion] The rapid method of LAMP detection of Salmonella was established.LAMP method was very rapid,sensitive and convenient,suitable for grass-roots generalization.This method built a technology platform for the detection of food-borne pathogens.

About this research paper

What this paper is about

[Objective] The research aimed to establish loop-mediated isothermal amplification (LAMP) technology for rapid detection of Salmonella.[Method] The primers were designed according to the Salmonella-specific gene (invA) sequence as the target sequence.And the sequence was amplified under the isothermal conditions.The reaction conditions were optimized including Mg2+ concentration,reaction temperature and time etc.And Salmonella stains were detected and identified.[Result] The results indicated that the best amplification conditions was 62 ℃ for 40 min when Mg2+ concentration was 2.0 mmol/L.The sensitivity of LAMP detection of Salmonella stains was 7.8 cfu/ml.[Conclusion] The rapid method of LAMP detection of Salmonella was established.LAMP method was very rapid,sensitive and convenient,suitable for grass-roots generalization.This method built a technology platform for the detection of food-borne pathogens.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] The research aimed to establish loop-mediated isothermal amplification (LAMP) technology for rapid detection of Salmonella.[Method] The primers were designed according to the Salmonella-specific gene (invA) sequence as the target sequence.And the sequence was amplified under the isothermal conditions.The reaction conditions were optimized including Mg2+ concentration,reaction temperature and time etc.And Salmonella stains were detected and identified.[Result] The results indicated that the best amplification conditions was 62 ℃ for 40 min when Mg2+ concentration was 2.0 mmol/L.The sensitivity of LAMP detection of Salmonella stains was 7.8 cfu/ml.[Conclusion] The rapid method of LAMP detection of Salmonella was established.LAMP method was very rapid,sensitive and convenient,suitable for grass-roots generalization.This method built a technology platform for the detection of food-borne pathogens.

Key concepts: Loop-mediated isothermal amplification, Salmonella, Isothermal process, Gene sequence, Chemistry, Molecular biology, Chromatography, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Reaction System Optimization for the Detection of Salmonella by Loop-mediated Isothermal Amplification Technology — Research Paper | ScholarLens