2011•Zhongguo linchuang yaolixue yu zhiliaoxueRequires access

HPLC-MS-MS determination of ritodrine in the human plasma and its pharmacokinetics

Xiangdong Peng

Open publisher page 0 citations

Abstract

AIM: To establish an HPLC-MS-MS method for determination of ritodrine in human plasma and to study the pharmacokinetics for two preparations in health volunteers.METHODS: The plasma was extracted with ethyl acetate.Separation was obtained on BDS Hypersil C18(3 μm,2.1 mm×50 mm)column with the mobile phase of water(1‰ formic acid)-methanol(20∶80) at the flow rate of 0.20 mL/min.Electrospray ionization source was operated in positive ion mode.Selected reaction monitoring mode with the transitions of m/z 288/270 and m/z 373.4/305.3 were used to quantify ritodrine and the internal standard,respectively.RESULTS:The calibration curve of ritodrine was linear in the range of 0.13-8 ng/mL and detection limit was 0.13 g/L.The intra and inter-day precision(RSD) were less than 12.5%.The absolute recoveries were above 75.4%.To study the pharmacokinetics and the relative bioavailability of two preparations of ritodrine,tablets were given to 18 healthy volunteers.The pharmacokinetics parameters were reported: Cmax were(6.1±1.9) and(5.8±2.1) ng/mL;tmax were(1.1±0.4) h and(1.2±0.4) h;t1/2 were(10±4) h and(9±5) h;AUC0-36 were(22±9) ng·mL-1·h and(21±8) ng·mL-1·h;AUC0-∞ were(25±10) ng·mL-1·h and(23±8) ng·mL-1·h.CONCLUSION: This method is convenient,sensitive,specific and suitable for pharmacokinetics and relative bioavailability study.

About this research paper

What this paper is about

AIM: To establish an HPLC-MS-MS method for determination of ritodrine in human plasma and to study the pharmacokinetics for two preparations in health volunteers.METHODS: The plasma was extracted with ethyl acetate.Separation was obtained on BDS Hypersil C18(3 μm,2.1 mm×50 mm)column with the mobile phase of water(1‰ formic acid)-methanol(20∶80) at the flow rate of 0.20 mL/min.Electrospray ionization source was operated in positive ion mode.Selected reaction monitoring mode with the transitions of m/z 288/270 and m/z 373.4/305.3 were used to quantify ritodrine and the internal standard,respectively.RESULTS:The calibration curve of ritodrine was linear in the range of 0.13-8 ng/mL and detection limit was 0.13 g/L.The intra and inter-day precision(RSD) were less than 12.5%.The absolute recoveries were above 75.4%.To study the pharmacokinetics and the relative bioavailability of two preparations of ritodrine,tablets were given to 18 healthy volunteers.The pharmacokinetics parameters were reported: Cmax were(6.1±1.9) and(5.8±2.1) ng/mL;tmax were(1.1±0.4) h and(1.2±0.4) h;t1/2 were(10±4) h and(9±5) h;AUC0-36 were(22±9) ng·mL-1·h and(21±8) ng·mL-1·h;AUC0-∞ were(25±10) ng·mL-1·h and(23±8) ng·mL-1·h.CONCLUSION: This method is convenient,sensitive,specific and suitable for pharmacokinetics and relative bioavailability study.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To establish an HPLC-MS-MS method for determination of ritodrine in human plasma and to study the pharmacokinetics for two preparations in health volunteers.METHODS: The plasma was extracted with ethyl acetate.Separation was obtained on BDS Hypersil C18(3 μm,2.1 mm×50 mm)column with the mobile phase of water(1‰ formic acid)-methanol(20∶80) at the flow rate of 0.20 mL/min.Electrospray ionization source was operated in positive ion mode.Selected reaction monitoring mode with the transitions of m/z 288/270 and m/z 373.4/305.3 were used to quantify ritodrine and the internal standard,respectively.RESULTS:The calibration curve of ritodrine was linear in the range of 0.13-8 ng/mL and detection limit was 0.13 g/L.The intra and inter-day precision(RSD) were less than 12.5%.The absolute recoveries were above 75.4%.To study the pharmacokinetics and the relative bioavailability of two preparations of ritodrine,tablets were given to 18 healthy volunteers.The pharmacokinetics parameters were reported: Cmax were(6.1±1.9) and(5.8±2.1) ng/mL;tmax were(1.1±0.4) h and(1.2±0.4) h;t1/2 were(10±4) h and(9±5) h;AUC0-36 were(22±9) ng·mL-1·h and(21±8) ng·mL-1·h;AUC0-∞ were(25±10) ng·mL-1·h and(23±8) ng·mL-1·h.CONCLUSION: This method is convenient,sensitive,specific and suitable for pharmacokinetics and relative bioavailability study.

Key concepts: Pharmacokinetics, Ritodrine, Chromatography, Chemistry, Cmax, Formic acid, High-performance liquid chromatography, Bioavailability

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC-MS-MS determination of ritodrine in the human plasma and its pharmacokinetics — Research Paper | ScholarLens