Design of automated field hyperspectral BRDF measurement system
Xin Li
Abstract
Xin Li
Abstract
With the development of remote sensing,the field BRDF(Bidirectional reflectance distribution function)measurements become more important.In the field,measurements require short time,enough positions and high spectral resolution.An automated measurement system is designed meeting the requirements.The system includes an automated goniometer and two spectroradiometers.The radius of goniometer is 2m.The goniometer system consists of a zenith,an azimuth,two servomotors and a PLC(Programmable logic controller).One spectrometer placed on goniometer sled measures reflectance,inputting irradiance is measured.Two spectroradiometers have the same flat field diffraction gratings and linear sensors and cover the 400-2500nm range with the resolution of 3.5nm(400-1000nm)and 12nm(1000-2500nm).System is controlled by IPC(Industrial personal computer)to make auto measurements.When performed with default auto set measurements is about 10 min.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
With the development of remote sensing,the field BRDF(Bidirectional reflectance distribution function)measurements become more important.In the field,measurements require short time,enough positions and high spectral resolution.An automated measurement system is designed meeting the requirements.The system includes an automated goniometer and two spectroradiometers.The radius of goniometer is 2m.The goniometer system consists of a zenith,an azimuth,two servomotors and a PLC(Programmable logic controller).One spectrometer placed on goniometer sled measures reflectance,inputting irradiance is measured.Two spectroradiometers have the same flat field diffraction gratings and linear sensors and cover the 400-2500nm range with the resolution of 3.5nm(400-1000nm)and 12nm(1000-2500nm).System is controlled by IPC(Industrial personal computer)to make auto measurements.When performed with default auto set measurements is about 10 min.
Key concepts: Goniometer, Bidirectional reflectance distribution function, Spectroradiometer, Optics, Remote sensing, Hyperspectral imaging, Spectrometer, Computer science