2006•Fluid MachineryRequires access

Experimental Study on Gas Turbine Inlet Air Cooling with CO_2-air Heat Exchanger

Jian Zhang

Open publisher page 0 citations

Abstract

CO_2-air heat exchanger was studied and tested and the heat exchanger's performance curve,relationship of factor j and f,reynolds number and the flow field distribution were got. Results show that the pressure drop is 5%~10% lower in cooling model than no heat exchange,and there is no much change about factor j and f despite of the heat transfer condition.When compared with the reference datum,the measured factor f coincides with it very well,and factor j is slightly lower than it.

About this research paper

What this paper is about

CO_2-air heat exchanger was studied and tested and the heat exchanger's performance curve,relationship of factor j and f,reynolds number and the flow field distribution were got. Results show that the pressure drop is 5%~10% lower in cooling model than no heat exchange,and there is no much change about factor j and f despite of the heat transfer condition.When compared with the reference datum,the measured factor f coincides with it very well,and factor j is slightly lower than it.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

CO_2-air heat exchanger was studied and tested and the heat exchanger's performance curve,relationship of factor j and f,reynolds number and the flow field distribution were got. Results show that the pressure drop is 5%~10% lower in cooling model than no heat exchange,and there is no much change about factor j and f despite of the heat transfer condition.When compared with the reference datum,the measured factor f coincides with it very well,and factor j is slightly lower than it.

Key concepts: Heat exchanger, Pressure drop, Thermodynamics, Mechanics, Heat transfer, Materials science, Inlet, Plate heat exchanger

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Study on Gas Turbine Inlet Air Cooling with CO_2-air Heat Exchanger — Research Paper | ScholarLens