2009CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (CHINESE VERSION)Requires access

Determination of Acetochlor Residue in Food by Gas Chromatography and Gas Chromatography-Mass Spectrometry

Zhen Dong

Open publisher page 3 citations

Abstract

A method was established to determination of acetochlor in 10 kinds of foods by gas chromatography and gas chromatography-mass spectrometry.The foods of grain and animal-based were extracted by acetonitrile and cleaned with GPC combined silica gel SPE cartridge,extracted by ethyl acetate and cleaned only with silica gel SPE cartridge for the foods of vegetables.Specially,onion was digested with microwave firstly.Then,extracted by ethyl acetate and cleaned with silica gel SPE cartridge.The final extract of food was analyzed by GC and GC-MS.The detection limit,both GC and GC-MS,were 0.01 mg/kg.Good linearity was obtained within the range of 0.01-0.16 mg/L with corelation coefficents of 0.9998 and 0.9997,respectively.When the spiked concentrations were 0.01,0.02 and 0.05 mg/kg,all the recoveries were 70%-102%.The relative standard derivations were no more than 10%.

About this research paper

What this paper is about

A method was established to determination of acetochlor in 10 kinds of foods by gas chromatography and gas chromatography-mass spectrometry.The foods of grain and animal-based were extracted by acetonitrile and cleaned with GPC combined silica gel SPE cartridge,extracted by ethyl acetate and cleaned only with silica gel SPE cartridge for the foods of vegetables.Specially,onion was digested with microwave firstly.Then,extracted by ethyl acetate and cleaned with silica gel SPE cartridge.The final extract of food was analyzed by GC and GC-MS.The detection limit,both GC and GC-MS,were 0.01 mg/kg.Good linearity was obtained within the range of 0.01-0.16 mg/L with corelation coefficents of 0.9998 and 0.9997,respectively.When the spiked concentrations were 0.01,0.02 and 0.05 mg/kg,all the recoveries were 70%-102%.The relative standard derivations were no more than 10%.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was established to determination of acetochlor in 10 kinds of foods by gas chromatography and gas chromatography-mass spectrometry.The foods of grain and animal-based were extracted by acetonitrile and cleaned with GPC combined silica gel SPE cartridge,extracted by ethyl acetate and cleaned only with silica gel SPE cartridge for the foods of vegetables.Specially,onion was digested with microwave firstly.Then,extracted by ethyl acetate and cleaned with silica gel SPE cartridge.The final extract of food was analyzed by GC and GC-MS.The detection limit,both GC and GC-MS,were 0.01 mg/kg.Good linearity was obtained within the range of 0.01-0.16 mg/L with corelation coefficents of 0.9998 and 0.9997,respectively.When the spiked concentrations were 0.01,0.02 and 0.05 mg/kg,all the recoveries were 70%-102%.The relative standard derivations were no more than 10%.

Key concepts: Chemistry, Chromatography, Gas chromatography, Ethyl acetate, Detection limit, Cartridge, Gas chromatography–mass spectrometry, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Acetochlor Residue in Food by Gas Chromatography and Gas Chromatography-Mass Spectrometry — Research Paper | ScholarLens