2009•Unpublished venueRequires access

Analysis of Mixed Emulsion of Avermetin B1 and Phoximby HPLC

Sun Ji-guo

Open publisher page 0 citations

Abstract

High efficiency chromatography was adopted for the separation and determination of avermectin B1 and phoxim in mixed emulsion on the Lichrospher-C18 column with methanol+water(85+15)as mobile phase and UV detector.Under the selected conditions,the retention times of avermectin B1 and phoxim were 28.5min and8.1 min respectively.RSD's(n=6) for avermectin B1 and phoxim were found to be 0.74% and 1.52%.And the average recoveries were 100.2% and 100.3%.The linear correlation coefficients were 0.9985 and 0.9989respectively.

About this research paper

What this paper is about

High efficiency chromatography was adopted for the separation and determination of avermectin B1 and phoxim in mixed emulsion on the Lichrospher-C18 column with methanol+water(85+15)as mobile phase and UV detector.Under the selected conditions,the retention times of avermectin B1 and phoxim were 28.5min and8.1 min respectively.RSD's(n=6) for avermectin B1 and phoxim were found to be 0.74% and 1.52%.And the average recoveries were 100.2% and 100.3%.The linear correlation coefficients were 0.9985 and 0.9989respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High efficiency chromatography was adopted for the separation and determination of avermectin B1 and phoxim in mixed emulsion on the Lichrospher-C18 column with methanol+water(85+15)as mobile phase and UV detector.Under the selected conditions,the retention times of avermectin B1 and phoxim were 28.5min and8.1 min respectively.RSD's(n=6) for avermectin B1 and phoxim were found to be 0.74% and 1.52%.And the average recoveries were 100.2% and 100.3%.The linear correlation coefficients were 0.9985 and 0.9989respectively.

Key concepts: Avermectin, Phoxim, Chromatography, Emulsion, High-performance liquid chromatography, Chemistry, Methanol, Pesticide

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Mixed Emulsion of Avermetin B1 and Phoximby HPLC — Research Paper | ScholarLens