2011•Chinese Rare EarthsRequires access

Determination of Europium by Fluorescence of Europium-Levofloxacin Hydrochloride System

Fan Jang-peng

Open publisher page 0 citations

Abstract

In medium HAc-NaAc,europium and levofloxacin hydrochloride formed a complex resulting in fluorescence quenching of levofloxacin hydrochloride,which established a new method for determination of europium.The maximum excitation wavelength was at 365nm,the maximum emission wavelength was at 500nm.The experimental results showed that the linear range was 2.00 × 10-7~2.80 × 10-5 mol·L-1,the minimum detection limit was 8.80 × 10-8 mol·L-1,and recovery rate was in range of 96.0% ~ 101.5%.This method has high sensitivity and good selectivity.

About this research paper

What this paper is about

In medium HAc-NaAc,europium and levofloxacin hydrochloride formed a complex resulting in fluorescence quenching of levofloxacin hydrochloride,which established a new method for determination of europium.The maximum excitation wavelength was at 365nm,the maximum emission wavelength was at 500nm.The experimental results showed that the linear range was 2.00 × 10-7~2.80 × 10-5 mol·L-1,the minimum detection limit was 8.80 × 10-8 mol·L-1,and recovery rate was in range of 96.0% ~ 101.5%.This method has high sensitivity and good selectivity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In medium HAc-NaAc,europium and levofloxacin hydrochloride formed a complex resulting in fluorescence quenching of levofloxacin hydrochloride,which established a new method for determination of europium.The maximum excitation wavelength was at 365nm,the maximum emission wavelength was at 500nm.The experimental results showed that the linear range was 2.00 × 10-7~2.80 × 10-5 mol·L-1,the minimum detection limit was 8.80 × 10-8 mol·L-1,and recovery rate was in range of 96.0% ~ 101.5%.This method has high sensitivity and good selectivity.

Key concepts: Europium, Excitation wavelength, Fluorescence, Hydrochloride, Linear range, Detection limit, Chemistry, Quenching (fluorescence)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Europium by Fluorescence of Europium-Levofloxacin Hydrochloride System — Research Paper | ScholarLens