2010Journal of Capital Medical UniversityRequires access

Study for the Biocompatibility of Decellularized Vascular Scaffold

Chunmin Li

Open publisher page 0 citations

Abstract

Objective To evaluate the biocompatibility of decellularized vascular scaffold prepared with Triton X-100 and trypsin.Methods In vitro and in vivo tests were performed to evaluate the biocompatibility of the decellularized vascular scaffold.The in vitro tests included direct-contact method and MTT assay,and the in vivo test was subcutaneous implant test.Results L929 cells grew well on the glass slide covered with decellularized vascular scaffold and in the solution of decellularized vascular matrix.The patches implanted subcutaneously in SD mice only caused slight inflammatory reaction after 2 weeks.Conclusion Decellularized vascular matrices prepared with Triton X-100 and trypsin had a good biocompatibility.

About this research paper

What this paper is about

Objective To evaluate the biocompatibility of decellularized vascular scaffold prepared with Triton X-100 and trypsin.Methods In vitro and in vivo tests were performed to evaluate the biocompatibility of the decellularized vascular scaffold.The in vitro tests included direct-contact method and MTT assay,and the in vivo test was subcutaneous implant test.Results L929 cells grew well on the glass slide covered with decellularized vascular scaffold and in the solution of decellularized vascular matrix.The patches implanted subcutaneously in SD mice only caused slight inflammatory reaction after 2 weeks.Conclusion Decellularized vascular matrices prepared with Triton X-100 and trypsin had a good biocompatibility.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the biocompatibility of decellularized vascular scaffold prepared with Triton X-100 and trypsin.Methods In vitro and in vivo tests were performed to evaluate the biocompatibility of the decellularized vascular scaffold.The in vitro tests included direct-contact method and MTT assay,and the in vivo test was subcutaneous implant test.Results L929 cells grew well on the glass slide covered with decellularized vascular scaffold and in the solution of decellularized vascular matrix.The patches implanted subcutaneously in SD mice only caused slight inflammatory reaction after 2 weeks.Conclusion Decellularized vascular matrices prepared with Triton X-100 and trypsin had a good biocompatibility.

Key concepts: Decellularization, Biocompatibility, Scaffold, In vivo, Biomedical engineering, In vitro, Chemistry, Tissue engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study for the Biocompatibility of Decellularized Vascular Scaffold — Research Paper | ScholarLens