Analysis of Problem Existing in Tuning Method for Arc Suppression Coil in Small Current Neutral Grounding System

Jinlong Zhang

Open publisher page 0 citations

Abstract

when a small current grounding system occurs single-phase ground fault,the arc suppression coil can effectively limit the fault current grounding point,making the ground arc self-extinguishing.Based on in the the principle of distribution network of neutral resonant grounding in small current grounding system,advantages and disadvantages of the three compensation status-under compensation,full compensation,over compensation,and pointed out that:off tuning degree of arc suppression coil should be adjusted according to the change of the system running the way,in order to achieve a reasonable compensation effect.Also this thesis looked forward to the future development trend of arc suppression coil.

About this research paper

What this paper is about

when a small current grounding system occurs single-phase ground fault,the arc suppression coil can effectively limit the fault current grounding point,making the ground arc self-extinguishing.Based on in the the principle of distribution network of neutral resonant grounding in small current grounding system,advantages and disadvantages of the three compensation status-under compensation,full compensation,over compensation,and pointed out that:off tuning degree of arc suppression coil should be adjusted according to the change of the system running the way,in order to achieve a reasonable compensation effect.Also this thesis looked forward to the future development trend of arc suppression coil.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

when a small current grounding system occurs single-phase ground fault,the arc suppression coil can effectively limit the fault current grounding point,making the ground arc self-extinguishing.Based on in the the principle of distribution network of neutral resonant grounding in small current grounding system,advantages and disadvantages of the three compensation status-under compensation,full compensation,over compensation,and pointed out that:off tuning degree of arc suppression coil should be adjusted according to the change of the system running the way,in order to achieve a reasonable compensation effect.Also this thesis looked forward to the future development trend of arc suppression coil.

Key concepts: Arc suppression, Ground, Electromagnetic coil, Compensation (psychology), Earthing system, Current (fluid), Arc (geometry), Limit (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Problem Existing in Tuning Method for Arc Suppression Coil in Small Current Neutral Grounding System — Research Paper | ScholarLens