The Retrofit of Pulverized Coal Burner to GB-65/39-M Boiler&Its Optimization Combustion Adjustment
Cheng Qing-gang
Abstract
Cheng Qing-gang
Abstract
After saving energy technical retrofit of BG-65/39-M boiler,the pulverized coal burner was changed to the type of STF-Ⅲ,namely two-way stable combustion pulverized coal burner.That resulted in combustion sta bi -lization when lean coal was combusted and heat efficiency was enhanced,also the ratio of carbon in flying ash was re-duced.The boiler may be performed stably at it60%specified load with out oil aid.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
After saving energy technical retrofit of BG-65/39-M boiler,the pulverized coal burner was changed to the type of STF-Ⅲ,namely two-way stable combustion pulverized coal burner.That resulted in combustion sta bi -lization when lean coal was combusted and heat efficiency was enhanced,also the ratio of carbon in flying ash was re-duced.The boiler may be performed stably at it60%specified load with out oil aid.