2011Unpublished venueRequires access

Determination of Cu,Pb,Zn and Fe in Tomb Soil Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry

Mao Zhen-cai

Open publisher page 0 citations

Abstract

Samples were digested with a mixed acid of HF-HCl-HNO3-HClO4,in a 5% Nitric acid solution,Cu,Pb,Zn,Fe in tomb soil samples were directly determined by inductively coupled plasma-atomic emission spectrometry(ICP-AES).The method overcomes the demerits of the traditional method i.e.,a tediously long analytical procedure and a difficult to control process.The detection limits of the method were: 2.0 μg/g for Cu,3.0 μg/g for Pb,2.0 μg/g for Zn and 10 μg/g for Fe.The reliability of the method has been tested by the determination of these elements in the National Standard Reference samples and the results are in good agreement with certified values with precisions of 1.5%~12.0% RSD(n=12).The method exhibits simplicity,rapidity,good reproducibility,wide linearity.It is suitable for the multi-element determination of dissolved mineral.

About this research paper

What this paper is about

Samples were digested with a mixed acid of HF-HCl-HNO3-HClO4,in a 5% Nitric acid solution,Cu,Pb,Zn,Fe in tomb soil samples were directly determined by inductively coupled plasma-atomic emission spectrometry(ICP-AES).The method overcomes the demerits of the traditional method i.e.,a tediously long analytical procedure and a difficult to control process.The detection limits of the method were: 2.0 μg/g for Cu,3.0 μg/g for Pb,2.0 μg/g for Zn and 10 μg/g for Fe.The reliability of the method has been tested by the determination of these elements in the National Standard Reference samples and the results are in good agreement with certified values with precisions of 1.5%~12.0% RSD(n=12).The method exhibits simplicity,rapidity,good reproducibility,wide linearity.It is suitable for the multi-element determination of dissolved mineral.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Samples were digested with a mixed acid of HF-HCl-HNO3-HClO4,in a 5% Nitric acid solution,Cu,Pb,Zn,Fe in tomb soil samples were directly determined by inductively coupled plasma-atomic emission spectrometry(ICP-AES).The method overcomes the demerits of the traditional method i.e.,a tediously long analytical procedure and a difficult to control process.The detection limits of the method were: 2.0 μg/g for Cu,3.0 μg/g for Pb,2.0 μg/g for Zn and 10 μg/g for Fe.The reliability of the method has been tested by the determination of these elements in the National Standard Reference samples and the results are in good agreement with certified values with precisions of 1.5%~12.0% RSD(n=12).The method exhibits simplicity,rapidity,good reproducibility,wide linearity.It is suitable for the multi-element determination of dissolved mineral.

Key concepts: Inductively coupled plasma, Chemistry, Nitric acid, Inductively coupled plasma atomic emission spectroscopy, Atomic emission spectroscopy, Analytical Chemistry (journal), Detection limit, Certified reference materials

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Cu,Pb,Zn and Fe in Tomb Soil Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry — Research Paper | ScholarLens