Exergy Analysis of Chiller Plant with Pre-cooling by Cooling Tower and Conventional Chiller Plant

Jiang Xiao-qiang

Open publisher page 0 citations

Abstract

In order to reduce the energy consumption of chiller plant at high temperature water source conditions,this paper presents the control strategy for pre-cooling high-temperature water with cooling tower.In order to explore the feasibility of this control and energy-saving potential,the exergy were analysis of the conventional chiller plant and new chiller plant with pre-cooling by cooling tower.The results show that when the water temperature is higher than a certain value,the exergy energy efficiency would be increased and the energy consumption of chiller plant with pre-cooling can be decreased,the saving energy would increase with water temperature.

About this research paper

What this paper is about

In order to reduce the energy consumption of chiller plant at high temperature water source conditions,this paper presents the control strategy for pre-cooling high-temperature water with cooling tower.In order to explore the feasibility of this control and energy-saving potential,the exergy were analysis of the conventional chiller plant and new chiller plant with pre-cooling by cooling tower.The results show that when the water temperature is higher than a certain value,the exergy energy efficiency would be increased and the energy consumption of chiller plant with pre-cooling can be decreased,the saving energy would increase with water temperature.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to reduce the energy consumption of chiller plant at high temperature water source conditions,this paper presents the control strategy for pre-cooling high-temperature water with cooling tower.In order to explore the feasibility of this control and energy-saving potential,the exergy were analysis of the conventional chiller plant and new chiller plant with pre-cooling by cooling tower.The results show that when the water temperature is higher than a certain value,the exergy energy efficiency would be increased and the energy consumption of chiller plant with pre-cooling can be decreased,the saving energy would increase with water temperature.

Key concepts: Chiller, Cooling tower, Exergy, Water chiller, Chiller boiler system, Environmental science, Water cooling, Chilled water